Box
Parameter / Control
Description
Admitted Ranges / Values
Status
Fan 2
Fan 2 speed indicator (values are expressed in rpm).
Used in SDTx20, SDTx50, SDTx201 and SDTx501.
Status
Fan 3
Fan 3 speed indicator (values are expressed in rpm).
Used in SDTx20, SDTx50, SDTx201 and SDTx501.
Status
Fan 4
Fan 4 speed indicator (values are expressed in rpm).
Used in SDTx501.
Status
CPU Fan
Shows the status of the CPU fan.
There are two types of errors:
Fan fault: fan speed equal to zero;
No Fan: the CPU fan is not connected.
FAN_OK
FAN_FAULT
NO_FAN
Status
FWD Power [dBm]
Output forward power indicator (values are expressed in dBm).
Status
Reflex Power [dBm]
Output reflex power indicator (values are expressed in dBm).
Opto & Relay
Relay 0
Selector of Relay 0 mode.
Alarm: indicator of an alarm
condition
Mode: indicator of operating mode
RF Status: indicator output RF
signal status (on/off)
Opto & Relay
Relay 1
Selector of Relay 1 mode.
Alarm: indicator of an alarm
condition
Mode: indicator of operating mode