Box
Parameter / Control
Description
Admitted Ranges / Values
General
Offset [Hz]
Output frequency offset (expressed in Hz).
Min: -200 kHz
Max: +200 kHz
General
Power [dBm]
Output power (expressed in dBm).
Output power ranges are device’s
definition dependant.
General
Power [W]
Output power (expressed in W).
General
Bandwidth [MHz]
The output channel bandwidth.
It depends on the device definition.
FWD Power
Thresholds
Warning [dB]
Forward power warning threshold expressed in dB.
Min: -16 dB
Max: 0 dB
FWD Power
Thresholds
Alarm [dB]
Forward power alarm threshold expressed in dB.
Temperature
Thresholds
Warning [°C]
Temperature warning threshold expressed in °C.
Min: 50 °C
Max: 74 °C
Temperature
Thresholds
Alarm [°C]
Temperature alarm threshold expressed in °C.
GbE 2 ch1/2 Tx
Enable send frame
Ethernet channel 1 transmission enabling.
Checked: Enabled
Not checked: Disabled