Table 18. Output window: Reflex Pwr Management
Box
Parameter / Control
Description
Admitted Ranges / Values
Reflex Pwr
Management
Number of attempts
The number of attempts to restore the system after RFL power has
gone over the alarm threshold.
Min: 0
Max: 255
Reflex Pwr
Management
Current number of
attempt
The current number attempt to restore the system.
Min: 0
Max: “Number of attempts”
Reflex Pwr
Management
Status
It shows the current status of the Reflex Power.
OK
Warning
Alarm
Reflex Pwr
Management
RFL Power High
It shows if RFL power goes over the alarm threshold.
Red: RFL power over the alarm
threshold
Grey: RFL power under the alarm
threshold
Reflex Pwr
Management
Timeout [s]
The timeout between two consecutive attempts.
Fixed to 10 seconds
Reflex Pwr
Management
Reset
This button resets the amplifier stage when it is switched off due to
a Reflex Power High alarm.
Reflex Pwr
Management
Reset Timeout [s]
If the RFL power control mechanism is in warning state and the
RFL power level doesn’t go over the alarm threshold for 30 minutes,
the amplifier stage is automatically reset.
Fixed to 30 minutes