Box
Parameter / Control
Description
Admitted Ranges / Values
OCXO
GPS Lock
OCXO locked to the external GPS reference.
Green: Locked
Grey: Not Locked
OCXO
Tracking
It shows whenever the OCXO is not locked to the selected
frequency reference or not.
Green: Locked
Grey: Not Locked
OCXO
SFN Ready
It shows whenever the OCXO is locked to the selected frequency
reference and the system is waiting for the OCXO stabilization or
not.
Green: SFN Ready
Grey: SFN Not Ready
OCXO
Holdover Ready
It shows whenever the Holdover function is available or not.
Green: Holdover Ready
Grey: Holdover Not Ready
OCXO
Holdover
It notifies that the equipment entered into Holdover mode
Green: Holdover On
Grey: Holdover Off
Holdover
Management
Holdover Enable
Enables the Holdover mechanism.
Checked: Enabled
Not checked: Disabled
Holdover
Management
Holdover Timeout [h]
Sets the timeout of the Holdover in hour.
Min: 0 h
Max: 24 h
Holdover
Management
Status
The status of the Holdover mechanism.
OFF
SFN Ready
Ready
ON
Expired