Owner's manual
INSTALLATION INSTRUCTIONS LR100VDK
ELECTRIC LATCH RETRACTION DEVICE KIT
MODELS: 3327A, 3348A,3527A, 3548A, 9827,
9847, 9849, 9857, 9927, 9947, 9949, 9957 & 9975
P:\INSTALLATION INST\SWITCH KIT\INST-LR100VDK.vsd REV H 10-13 Page 1
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com
Step 1
Remove Von Duprin installed
mechanical dogging assembly.
VON DUPRIN MECHANICAL
DOGGING ASSEMBLY
Step 2
Slide the LR100 Electric Latch Retraction
assembly into device and attach the linkage
to the latch retraction rod.
ELECTRICAL DATA
24VDC @ 700/200mA
RED (+) BLK (-)
PATENT PENDING
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: service@sdcsecurity.com
NOTE Retro-Fitting Vertical Rod Devices:
Before retro-fitting an electric latch assembly into a
vertical device, the following must be done to ensure
proper alignment. Disconnect the vertical rods from
the device head. Install the electric latch assembly
as shown above. Once the ELR is properly installed
energize it so that the push pad is dogged down, by
doing so it will allow for proper alignment for the
vertical rods. Finally reconnect the vertical rods to
the device and make the proper adjusments.
INSTRUCTIONS CONTINUED ON BACK OF PAGE
CLEVIS
CLEVIS PIN
VON DUPRIN LATCH
RETRACTION ROD
LR100 LINKAGE
Disconnect vertical rods from the
Device head