User's Manual

*Mouse resolution : 500DPI (Default)
Mechanical performance
Mechanical performanceMechanical performance
Mechanical performance
1) Operation system : Non-lock tactile rubber feeling
2) Stroke :
a)KBD key top :3.0 ± 0.5mm with an applied measurement load of 200gf.
b)mouse switch : 1.0mm ± 0.3mm 150gf(Max)
3) Operation force : Relationship between the operating force and travel is given by the following
graph ;
The operation force has a tolerance of 50 ± 20 gf.
4) Drop force : 5 ~ 35 gf
5) Operating feeling
No definite stickiness or other abnormality shall be allowed when force is applied with a finger on
the keytop center at the rate of 3 times a second.
6) End stroke strength
End stroke should withstand a static load of 500 gf applied on the key stem in the perpendicular
direction for a minute.
7) Keytop full strength
A key op shall not be pulled off unless applying a force of 1 ~ 2Kg range in the vertical direction.
8) Wrap (due to the applying the force)
Shall be 5 mm or less when applying 1 kgf static force to the center of keyboard. The keyboard is
held by static rails at space bar side and opposite side.