Installation manual

HIGH PRESSURE PUMP INSTALLATION
High Pressure Pump RPM
Minimum Maximum Recommended
1250 1800 1725
*Decreasing the RPM of the pump will simply decrease the production of fresh water.
To determine your generator’s operating RPM, refer to the AR North America chart below.
►►►Go back to page 6 and write your generators RPM in the gold-colored box for future reference..
Sea Clear Watermakers™ Manual - Version 1.1-G Page 27
Bracket Requirements
Before installing the high pressure pump, you’ll need a bracket to mount it to the generator.
The pump must be mounted as level as possible with the oil dipstick on top of the unit.
The pump can be turned in either direction.
The bracket should be made of mild steel and painted prior to installation.
The bracket should include a method for tensioning the belt.
►►► It is recommended that a quali ed metal fabricator or mechanic build and install the
bracket.