Installation Guide

A. Use a listed wire connector to connect the fixture hot wire (black
wire, or round and smooth tracer) to the supply hot wire.
B. Use a listed wire connector to connect the fixture common wire
(white wire, or square and rigid) to the supply common wire.
C. Gently try to remove the wires from the connector. If you can
remove the wires, carefully re-do the wiring connection.
S
ecure mounting bar (A) to outlet box with outlet box screws (not
supplied). Thread nut (B) on nipple (C) so that 3 threads are exposed
above nut (B). Thread nipple (C) into mounting bar (A) and secure
with nut (B). Thread screw collar (E) to nipple (C).
STEP 1:
U
sing 2 pairs of pliers or chain breaks, open one link of chain (H) and
connect it to the fixture loop (I) at the top of the fixture. Please be
sure to open chain link outwards. Do not twist.
STEP 2:
Slide the screw collar ring (F) and canopy (G), in that order, over
chain (H). Open one link on the other end of the chain (H) and attach
it to the screw collar (E) which has been mounted to the nipple (C).
BE SURE TO CLOSE ALL CHAIN LINKS COMPLETELY.
STEP 3:
INSTALLATION HC-1570
STEP 4:
STEP 5:
GROUNDING INSTRUCTIONS
:
Connect the supply ground wire, fixture ground wire, and mounting bar
ground wire (pre attached) using the supplied wiring connector. Gently try
to remove the wires from the connector. If you can remove the wires,
carefully re-do the wiring connection.
A
fter wires are connected, tuck them carefully inside outlet box.
Raise canopy (G) against ceiling and thread the screw collar ring (F)
to the screw collar (E).
Make sure no bare wires can be seen outside wire connectors.
I
nstall lamp (not supplied).
FINAL ASSEMBLY
STEP 6:
S
TEP 7:
Raise cage assembly (L) to fixture and secure using supplied
retaining screws (M).
STEP 8:
IMPORTANT: DO NOT ATTACH FIXTURE DIRECTLY TO OUTLET BOX
WITHOUT THE USE OF A MOUNTING BAR.