INSTALLATION INSTRUCTIONS 030303 A-724L
(1) CUTTING A HOLE
Locate the center of proposed opening on your
tile or ceiling material and mark it. Use the
template provided to draw a 4 3/8” dia. circle
around the center point. Cut along the circular
line.
(2) ELECTRICAL CONNECTION
Junction box contains two wires, a black (hot)
and white (neutral) which must be spliced to
the house wires. MAKE SURE TO SPLICE
WHITE TO WHITE AND COLORED OR BLACK
TO BLACK. After splicing has been completed,
insert wires carefully into junction box. Connect
green ground wire to green grounding pigtail in
junction box (see Drawing A). Replace cover.
(3) INSTALLING FIXTURE TO CEILING
Slip outlet box, then housing through hole in
ceiling. Install (3) clips through “T” slots in
housing and pull down to firmly press clip
against ceiling.
CAUTION: SEE WARNING
INSTRUCTIONS ON BACK BEFORE
PROCEEDING
WARNING: FOR FIXTURES PROVIDED WITH
75˚ C. OR 90˚ C. SUPPLY WIRE WARNING
ONLY (THESE WARNINGS ARE PROVIDED ON
THE U.L. LABEL AND ON THE FIXTURE
CARTON).
WARNING: RISK OF FIRE. MOST DWELLINGS
BUILT BEFORE 1985
HAVE SUPPLY WIRE RATED 60˚ C. CONSULT
A QUALIFIED ELECTRICIAN BEFORE
INSTALLING.
A
B
C
D
POWER
LEAD
GROUND
CLIP
“T” SLOT
1/2” MIN.
1115 NON-IC REMODEL HOUSING
CAUTION!
INSULATION MUST BE KEPT A MINIMUM
OF 3” AWAY ON SIDES AND NO
INSULATION ON TOP OF THIS FIXTURE
BY PASSING THE SOCKET BRACKET STOP MAY CAUSE
THE LIGHT TO CYCLE ON AND OFF OR NUISANCE TRIP.