Installation Guide

INSTALLATION HC-226
FINAL ASSEMBLY
STEP 1:
STEP 4:
I
MPORTANT: DO NOT ATTACH FIXTURE DIRECTLY TO OUTLET
BOX.
Using outlet box screws (not supplied) fasten mounting bar (D) to
outlet box through slots in mounting bar (D).
STEP 1:
Make sure no bare wires can be seen outside wire connectors.
Place glass (J) in holder (K) and secure in place by screwing thumb
screws (L), or by screwing on retaining ring (M), which ever is
applicable.
Install lamps.
After wires are connected, tuck them carefully inside outlet box.
Push the fixture firmly over the mounting nipple (F) and against the
wall. Secure canopy (I) in place with cap nut (H).
STEP 2:
STEP 3:
STEP 4:
STEP 2:
Thread nut (E) onto nipple (F) so that 5 threads are exposed above
n
ut (E). Thread that end of the nipple (F) into mounting bar (D) and
tighten nut (E) against mounting bar (D).
A
. Take note of the color of the wire(s) on your fixture. Identify
which group your fixture wire(s) falls into and connect the wires
according to the directions below:
STEP 3:
*Note: When parallel wire is used, the tracer wire is square shaped
or ridged and less tracer wire is round in shape or smooth.
(Seen best when viewed from wire end.)
T
o separate wires, grasp
the ends of each wire and pull apart.
B. Take your fixture wire(s) from group A and place evenly against
the black wire from the outlet box. DO NOT twist wires together
before using wire connectors.
C. Fit a wire connector (not supplied) over the wires and screw the
connector clockwise until you feel a firmness.
D.
T
ry gently to pull the connector of
f the wires. If you can pull the
connector off, carefully re-do steps B and C, as above and check
again for a firm connection.
E. Connect the fixture wire from group B to the white wire from the
outlet box in the same manner.
GROUNDING INSTRUCTIONS: The green grounding screw (G) is
t
o be inserted into the hole with two raised dimples provided on the
mounting bar (D). Wrap the ground wire from the fixture (if supplied) and
the ground wire from the outlet box (bare metal or green
i
nsulated wire) around the green grounding screw (G) on the
mounting bar (D) if uninsulated wire is on the mounting bar (D),
connect the ground wire from the fixture (if supplied) and the outlet
b
ox to it using a small wire connector (not supplied).
NOTE: Underwriters Laboratories (U.L.) does not require all fixtures to
have ground wires. These fixtures still meet all U.L. specifications. The
l
isting mark of Underwriters on the product identifies products
manufactured under its listing and Follow-Up Service Programs.
NEVER CONNECT GROUND WIRE TO BLACK OR WHITE
POWER SUPPLY WIRES.
GROUP A: CONNECT TO BLACK
HOUSE WIRE
BLACK
WHITE
*
PARALLEL WIRE (ROUND & SMOOTH)
WHITE OR GREY
WITH TRACER
BROWN,
GOLD OR BLACK
WITHOUT
TRACER
BROWN,
GOLD OR BLACK WITH TRACER
WHITE OR GREY WITHOUT TRACER
*PARALLEL WIRE (SQUARE & RIDGED)
GROUP B: CONNECT TO WHITE
HOUSE WIRE
CLEANING
To clean, wipe fixture body with a soft cloth. Clean glass with a mild
soap. Do not use abrasive materials such as scouring pads or
powders, steel wool, or abrasive paper.
ORDERING PARTS
Keep this sheet for future reference, and in case you need to order
replacement parts. All parts for this fixture can be ordered from place
of purchase. Be sure to use exact wording from illustration when
ordering parts.