Use and Care Guide
Document Rev: A00
Date: 01-Dec-2012
KTEB-220-1-TP-EMI /G
Ballast Type
Electronic
Starting Method
Rapid Start
Lamp Connection
Parallel
Input Voltage
120Vac ± 10%
Input Frequency
60Hz
ELECTRICAL SPECIFICATIONS:
Lamp Type
No. of
Lamp
Input Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Efficacy
Factor
Max.
THD %
F20T8 2 34 0.50 0.57 1.52 0.88 2.59 130
F20T12 2 34 0.50 0.57 1.52 0.88 2.59 130
F18T8 2 34 0.49 0.57 1.54 0.94 2.76 130
F17T8 2 36 0.52 0.58 1.52 1.00 2.78 130
F15T8 2 31 0.46 0.56 1.57 1.00 3.23 130
F15T12 2 31 0.46 0.56 1.57 1.00 3.23 130
F14T8 2 27 0.41 0.54 1.60 0.88 3.26 130
F14T12 2 27 0.41 0.54 1.60 0.88 3.26 130
PERFORMANCE:
- Sound Rated: A
- Minimum Starting Temperature: 0 , -18
- Maximum Case Temperature: 167 , 75
- Transient Protection meets ANSI/IEEE C62.41 Cat. A
- Lamp end-of-life protected
- Meets FCC Part 18 (Class B) Consumer Limits
- 3-Year Warranty
APPROVALS:
- UL, cUL 935 listed
- Energy Star V1.1
PHYSICAL DIMENSIONS:
Length (L): 6.46”
Width (W): 1.37”
Height (H): 1.00”
Mounting (M) 6.00”
Lead Length:
White, Black 13” x 13”
Blue 18” x 18”, 8” x 8”
Red 18” x 18”, 8” x 8”
WIRING DIAGRAM: HOT SPOT LOCATION:
BLUE
BLUE
RED
RED
BLACK
LINE
WHITE
4.0”
0.375”
BLUE
BLUE
RED
RED
LAMP
WHITE
Red
BLACK
Red
BALLAST
LINE
BLUE
BLUE
LAMP
Red
Red
BLUE
BLUE