STARTER SET 9888/9889/9890
Select the desired location to mount transformer (not in contact with
insulation and away from oven or any other source of intense heat,
including other transformers).
Use screws to mount transformer to surface. Transformer can be mounted
in any direction. The wattage load on each output must be a minimum of
15w for the transformer to operate, but must not exceed 60w.
NOTE: Switch must be mounted a least 1 1/2” away from any
metal parts.
NOTE: When parallel wire (SPT I and SPT II) is used, the tracer
wire is square shaped or ridged and the non-tracer wire is
round in shape or smooth (seen best when viewed from wire
end).
1.
Split 120v cord as illustrated (FIGURE 4). Cut the non-tracer
(or smooth) wire. Be sure to cut only the smooth non-tracer wire.
2. Remove the screw from the switch and take the switch apart.
3. Place the wires in part A (without the wheel) as shown. Tuck
the cut wire down one end on each side of the barrier.
4. Press both halves of the switch back together. Note that the
points pierce insulation to make contact with copper inside wire.
5. Place screw back into center hole and secure in place with nut.
1. Cut off end of 120v cord cleanly and evenly. CAUTION: Do not
separate wires. Do not remove or damage insulation
(Figure 3)
2. Press cord, with ridged side to the right (tracer wire), down and
into front of plug.
3. Press cord down onto metal prongs.
4. Slide plug cover over cord and plug until plug cover is centered
over plug.
120V SWITCH
POINTS
PART A
SCREW
NUT
NON-TRACER WIRE
TRACER WIRE
COVER
NOTE: (If Applicable). The transformer has an 8 foot 120 volt
cord with a plug molded at the end (FIGURE 1).
If you require the length of the 120 volt cord to be shorter, cut
and discard the excess 120 volt cord with molded plug.
Follow
the instructions below on how to install 120 volt quick-connect
plug.
TO PLUG (TO LIGHTS)
FROM 120V PLUG
120 WATTS
(2 x 60 WATT)
TRANSFORMER
120V
CORD
120V
CORD
THE INPUT/OUTPUT VOLTAGE IS
MARKED ON THE TRANSFORMER
12V
120V
FIGURE 2
FIGURE 3
FIGURE 4
WARNING: Be sure the electricity to the wires you
are working on is shut off; either the fuse removed
or the circuit breaker off.
U.S. PAT. # 5,465,199
CAUTION: TO PREVENT THE RISK OF FIRE,
DO NOT INSTALL CLOSER THAN 2” TO CABINET
WALL OR IN A COMPARTMENT SMALLER
THAN 6” X 6” X 22”.
043003
(IF APPLICABLE - CONNECT
SECOND PLUG TO LIGHTS)
TRANSFORMER
FIGURE 1
TRANSFORMER
12V WIRES
12V PLUG
OUTLET
120V CORD
120V
QUICK-
CONNECT
PLUG
120V PLUG
(IF APPLICABLE)