System information
Coastal 24 & 30 Ku-Band TVRO Computer Interface
8-3
Control Function
^0080↵
↵↵
↵ Start bootloader.
^0086
↵
↵↵
↵ Disable DACP updates and enter diagnostic test mode.
^0090
↵
↵↵
↵ Reboot PCU.
edddd
↵
↵↵
↵ Set elevation target to ddd.d degrees.
jdddd
↵
↵↵
↵ Set pseudo azimuth target to ddd.d degrees.
mnn
↵
↵↵
↵ Set Model type to nn (range 18, 24, 30).
pnnn
↵
↵↵
↵ Set POLANG target to nnn degrees (range, 20 to 160, nominal setting of 90).
tnnnn
↵
↵↵
↵ Set THRESHOLD to nnnn counts (0-4095).
unnn
↵
↵↵
↵ Set Auto Threshold to nnn counts (range 000 to 255, nominal 150).
a(k)aaaaaa
↵
↵↵
↵ Set Satellite (k) Name to aaaaaa.
b(k)nnnnn
↵
↵↵
↵ Set Satellite (k) Baud (symbol) rate to nnnnn.
f(k)nnnn
↵
↵↵
↵ Set Satellite (k) primary tuning frequency (950-2047)..
g(k)ddddW
↵
↵↵
↵ Set Satellite (k) longitude to ddd.d E/W degrees.
h(k)nnnn
↵
↵↵
↵ Set Satellite (k) Alt tuning frequency (950-2047) ** Not presently used, set to 0
n(k)xxxx
↵
↵↵
↵ Set Satellite (k) Network ID (NID) to xxxx (0000-FFFF).
o(k)[-]nn
↵
↵↵
↵ Set Satellite (k) Polang Offset +/- nn degrees
C Tracking ON
D Tracking OFF, Search OFF.
N Select next visible satellite
W Write parameters to NVRAM
Y Restore DACP operation
Z Send selected satellite tuning parameters to DVB receiver.
2 Elevation DOWN
8 Elevation UP
4 Azimuth LEFT
6 Azimuth RIGHT
1 AZ rate bias DOWN (factory diagnostic only)
3 AZ rate bias UP (factory diagnostic only)
5 Tilt Bias reset
0 Set tilt Bias to current tilt readings (zero tilt display)
7 Toggle Search ON/OFF (no parameter initialization)
9 Reverse Search Azimuth Direction
Abbreviations
aaaa Alpha-Numeric characters (1-9, A-Z, a-z)
dddd Decimal digits in tenths of degrees. Equal to ddd.d degrees.
DDmm Decimal degrees (0-90 or 0-180) and decimal minutes (00-59).
nnnn Decimal digits in counts. Range is nominally 0-4095 or 950-2047
nnn Decimal digits in counts or degrees. Range is 0-255.
xxxx Hexadecimal digits. Range is 0000-FFFF.
k Satellite index (1-6)
↵
↵↵
↵ or cr Enter or Carriage Return