System information

Maintenance & Troubleshooting DAC-2202 Antenna Control Unit
7-14
4. Ensure that the “RAM Loader” displays
as PDL-Generic.bin
5. Ensure that the “User Program” field
displays the file location & is current
software version. If correct, skip ahead
to step 9. If incorrect, continue on to
step 6
6. Select the icon
7. Browse to the location where the bin file
is stored.
8. Select the icon.
9. Click on “Ping/Config” then “UDP Port”
and enter 3000
10. Press “Reset” key on front panel of ACU.
11. Click on “Ping/Config” then “Ping
Specific IP” and enter the address of the
DAC2202 then click OK. (One time only)
12. Verify “Search/Ping Response from:
192.168.30.195 port 3000: DAC-2202
UDP Download Interface” is displayed in
bottom Dialog Box and skip ahead to step
13 if this step fails continue on to 12a.
12a. If “Searching for boards on port 3000.”
continuously displays on bottom dialog box after
sending Ping Request, then the Comm IF PCB is
NOT communicating with computers Ethernet
port.
Possible Failure
: Network Download Utility not
configured correctly
Check: Verify IP address and Port Number
entered in step 11 matches that of the ACU.
(Factory Default IP address is 192.168.30.195
with a Subnet mask of 255.255.255.248)