Installation manual

Installation 6009-33 Installation Manual
3-5
3.5.1.
General Cautions & Warnings
CAUTION - Electrical Shock Potentials exist on the Gyro Compass output
lines. Assure that the Gyro Compass output is turned OFF when handling and
connecting wiring to the Terminal Mounting Strip.
CAUTION - Allow only an authorized dealer to install or service the your Sea Tel
System components. Unauthorized installation or service can be dangerous and may
invalidate the warranty.
3.5.2.
Prepare the Rack (or other location) for the ACU, Terminal Mounting Strip and base multiplexer panel.
Prepare the mounting locations for the other Below Decks Equipment throughout ship.
Preparing BDE Location
3.5.3.
System Configuration
Figure 3-1 Series 09 Simplified Block Diagram
3.5.4.
1. Install the ACU in the front of the standard 19” equipment rack or other suitable location. The DAC-
2202 ACU is one rack unit high.
Installing the Below Deck Equipment
2. Install the Terminal Mounting Strip on the rear of the 19” equipment rack or other suitable location
that is within 6 feet of the rear panel connections of the ACU. It also is one rack unit height.
3. Install the Base Multiplexer Panel on the rear of the 19” equipment rack or other suitable location
that is within 6 feet of the rear panel connections of the ACU. It is four rack unit height.