Installation manual

Setup Other Parameters 6009-33 Installation Manual
13-1
13. Setup Other Parameters
13.1. SETUP Parameter display and entry menus.
Press and hold BOTH the LEFT and the RIGHT arrow keys for 6 seconds to access to the
system setup parameters (at the EL TRIM selection). Press BOTH the LEFT and the RIGHT
arrow keys momentarily to access to the SAVE NEW PARAMETERS parameter.
Access is only required after installation or repairs of your antenna system. These parameters
should only be changed by an authorized service technician.
CAUTION: Improper setting of these parameters will cause your system to not perform properly. Also refer to the
SETUP section of your Antenna manual.
13.2. 5V OFFSET (May not be in your software)
CCW 5v Polang servo position reference. Refer to your antenna manual.
To manually update, press the LEFT arrow key to bring the cursor up under the least significant character. Continue to
move the cursor until the desired character to be edited is underscored (selected). Use the UP or DOWN arrow keys to
increment or decrement the selected character.
Use the LEFT or RIGHT arrow key to move the cursor left or right to select other characters to modify. When you are
finished modifying press ENTER to execute the new value OR press NEXT to abort and exit setup mode.
13.3. 5V SCALE (May not be in your software)
90 degree 5V Polang servo motion scale factor.
To manually update, press the LEFT arrow key to bring the cursor up under the least significant character. Continue to
move the cursor until the desired character to be edited is underscored (selected). Use the UP or DOWN arrow keys to
increment or decrement the selected character.
Use the LEFT or RIGHT arrow key to move the cursor left or right to select other characters to modify. When you are
finished modifying press ENTER to execute the new value OR press NEXT to abort and exit setup mode.
13.4. REMOTE COMMAND
This parameter was used to issue diagnostic commands to the PCU, but is superseded by the use of DacRemP
diagnostic software that your dealer will use when necessary.
13.5. REMOTE MONITOR
This parameter was used to monitor the results of a diagnostic command which was sent to the PCU.
13.6. To Disable/Enable DishScan
When running a beam pattern test, a programmed sweep for NOC/Satellite Operator, balancing the antenna or
motor diagnostics where you want the drives (AZ, EL & CL) not to be oscillating you will have to disable DishScan.
Select the DISHSCAN parameter window on the ACU:
1. Press the RIGHT arrow, then press the UP arrow and last press the ENTER key to turn DishScan mode ON.
2. Press the RIGHT arrow, then press the DOWN arrow and last press the ENTER key to turn DishScan Mode
OFF.
If you change this remote parameter, you must save the change using REMOTE PARAMETERS.
If DishScan is OFF and the Step Integral parameter is set to 0000, you will get a constant ERROR 0016 (DishScan error)
and you will see zeros flashing in the lower left of the Azimuth and Elevation ENTRY menu displays. This is a visual
indication that DishScan is turned OFF.
Always assure that you turn DishScan back ON when returning to normal operation.