Installation manual

Setup Other Parameters 6009-33 Installation Manual
13-9
Number Description
1
Click to redirect to the Port Settings Page. This page presents the TCP connection and
baud rate settings for the Comm If Module.
2
Click to redirect to the DAC Parameters 1 Page. This page presents the current ACU
configuration parameter values stored in the 68HC08 processor.
3
Click to redirect to the DAC Parameters 2 Page. This page presents the current Satellite
Tracking parameter values stored in the 68HC08 processor. This page also contains the
currently defined blockage zones (Az Limits 1-6).
4
Click to redirect to the Status page. This page presents current system status, including
Tracking condition, Antenna Position, Vessel Location / Orientation, and decoded error
conditions.
5
Click to redirect to the Home page. This page presents current system software versions
and antenna model configuration.
6
Click the “RELOAD” button to refresh the screen to the current ACU parameter values
7
Click the SAVE button to store all currently displayed parameters to Flash (68HC08).
8
These fields present the ACU parameter values currently stored in Flash. To change a
parameter value mouse click inside the entry field and type in the desired value and click
on the SUBMIT button. If the parameter value change(s) causes desirable operation click
on the SAVE button to store value to Flash. Refer to Setup (Section 5) of this manual for
acceptable range values and definitions of these parameters.
9
This List box presents the decoded System Type parameter currently stored in Flash.
When the entered System Type value enables an available ACU system options it is
highlighted in blue.
No changes to this list box is possible, any desired changes to the System Type parameter
are done via the System Type entry field.
10
This drop-down list box presents the Gyro Type parameter value currently stored in Flash.
To change to Gyro type, mouse click on the selection arrow and choose the desired gyro
source which is interfaced with the DAC2202.
11
Click the SUBMIT button to transfer all currently displayed parameters to the 68HC08
module operating software variables table. NOTE: The submit button will not store the
values to flash, an ACU reset (hard or soft) will revert to the old settings.