Operating instructions

95
At this point, install a hose pincher on
bleed outlet hose.
RX DI MODELS
1. Bleed outlet hose
GTX DI MODELS
1. Bleed outlet hose
Continue to pour until antifreeze flows
in air compressor water outlet hose.
RX DI MODELS
1. Air compressor water outlet hose
GTX DI MODELS
1. Air compressor water outlet hose
Remove pinchers in this order to allow
proper flow of antifreeze.
1. Bleed outlet hose.
2. Crankcase cooling cover outlet hose.
3. Engine cylinder drain hose.
4. Water outlet hose.
Pour approximately 200 mL (7 oz) of
antifreeze in the water regulator valve
supply hose to allow antifreeze flow-
ing through the valve and into muffler
to protect it.
Remove temporary hose and recon-
nect engine water outlet hose.
F07E0OY
1
F18E0EY
1
F07E0NX
1
1
F18E01Y