Instructions / Assembly

·PUMP WILL NOT START/BLOWS CIRCUIT:
Electrical connections, fuse or breaker, main switch, and ground connection
Is voltage present at the switch? Bypass the pressure switch. Does the pump operate?
Charging Systems for correct voltage (±10%)..
For an open circuit, or motor; or improperly sized wire.
For seized or locked diaphragm assembly (water frozen?).
·WILL NOT PRIME/SPUTTERS: (No discharge/Motor runs)
Is the strainer clogged with debris?
Is there water in the tank?
Is the inlet tubing/plumbing severely restricted or kinked? Restrictive valves?
Proper voltage with the pump operating (±10%)
For debris in pump inlet /outlet valves or swollen/dry valves.
Pump housing for cracks or loose drive assembly screws.
TROUBLESHOOTING
Vibration induced by driving and boating can loosen plumbing, strainers and pump hardware.
Check for system components that are loose.
For restrictive plumbing and flow restrictions in faucets/shower heads.
Water filter/purifier should be on separate feed line.
·PUMP WILL NOT SHUT-OFF/RUNS WHEN FAUCET IS CLOSED:
Output side (pressure) plumbing for leaks, and inspect for leaky valves or toilet.
For air trapped in outlet side or pump head.
For incorrect voltage to pump (±10%).
For loose drive assembly or pump head screws.
Are the valves held by debris or is the rubber swollen?
Pressure switch operation.
·RAPID CYCLING:
·NOISE OR ROUGH OPERATION:
For plumbing which may have vibrated loose.
For a restricted inlet (clogged strainer, kinked hose, restrictive valves).
Is the pump plumbed with rigid pipe causing noise to transmit?
Does the mounting surface amplify noise (flexible)? Does it bang like a drum?
For mounting feet that are loose or are compressed too tight.
For air in the system. Check all fixtures for air and bleed system.
The motor with pump head removed. Is noise from motor or pump head?
3. Using a pan to catch the remaining water, remove the plumbing at the pump’s inlet/outlet
ports. Turn the pump ON, allowing it to operate until the water is expelled. Turn OFF power to
the pump once the plumbing is emptied. Do not reconnect the pump plumbing. Make a note at
tank filter as a reminder: “plumbing is disconnected.
4. All faucets must be left open to guard against any damage.
5. Potable anti-freeze maybe poured down drains and toilets to protect p-traps and toilet seals.
Sanitize the plumbing system before putting the plumbing system back in service.
page 3 of 4
Item
1
2
3
4
Description
Pressure switch assembly
Pump head assembly
Motor
Pump housing
Quantity
1
1
1
1
We warrant our RV/Marine/Agriculture Water Pumps to be free from material and
workmanship defects under normal use and service for a period of one (1) year from the date of
purchase. In the absence of proof of purchase the warranty is one (1) year from the date of
manufacture indicated on the motor nameplate. Not to exceed (1) one year in any event. The
limited warranty will not apply to pumps that were improperly installed, misapplied, or are
incompatible with components not manufactured by us. Pump failure due to foreign debris is
not covered under the terms of this limited warranty. We will not warrant any pump that is
physically damaged. or altered outside our factory. Warranty claims may be resolved by an
authorized dealer service center, or by one of our service center. Returns are to be shipped with
charges pre-paid. Package all returns carefully. We will not be responsible for freight damage
incurred during shipping to a service center. Our obligation under this warranty policy is limited
to the repair or replacement of the pump. Pumps found not defective ( under the terms of this
limited warranty) are subject to charges to be paid by the returnee for the testing and
packaging of tested goodunits. Warranty returns will be shipped on a freight allowed basis.
We reserve the right to choose the method of transportation. We are not responsible nor will it
reimburse for labor necessary to remove and reinstall a pump, if found defective.
·LEAKS FROM PUMP HEAD OR SWITCH:
For loose screws at switch, by-pass or pump head.
Switch diaphragm ruptured or pinched.
For punctured diaphragm if water is present in the drive assembly.
EXPLODED VIEW-NO REPAIR KITS AVAILABLE
LIMITED WARRANTY
page 4 of 4