Product manual
Table Of Contents
- Barracuda 18FC Disc Drive
- ST118273FC
- Product Manual, Volume 1
- Barracuda 18FC Disc Drive
- ST118273FC
- Product Manual, Volume 1
- Revision status summary sheet
- Contents
- 1.0 Scope 1
- 2.0 Applicable standards and reference documentation 3
- 3.0 General description 5
- 4.0 Performance characteristics 9
- 5.0 Reliability specifications 13
- 6.0 Physical/electrical specifications 19
- 7.0 Defect and error management 25
- 8.0 Installation 27
- 9.0 Interface requirements 33
- 9.1 FC-AL features 33
- 9.1.1 Fibre Channel link service frames 33
- 9.1.2 Fibre Channel task management functions 33
- 9.1.3 Fibre Channel task management responses 33
- 9.1.4 Fibre Channel port login 34
- 9.1.5 Fibre Channel port login accept 35
- 9.1.6 Fibre Channel Process Login (PRLI) 35
- 9.1.7 Fibre Channel Process Accept (ACC) 35
- 9.1.8 Fibre Channel fabric login 36
- 9.1.9 Fibre Channel fabric accept login 37
- 9.1.10 Fibre Channel Arbitrated Loop options 38
- 9.2 Dual port support 38
- 9.3 SCSI commands supported 39
- 9.4 Miscellaneous operating features and conditions 45
- 9.5 FC-AL physical interface 46
- 9.5.1 Physical characteristics 46
- 9.5.2 Connector requirements 47
- 9.5.3 Electrical description 48
- 9.5.4 Pin descriptions 48
- 9.5.5 FC-AL transmitters and receivers 49
- 9.5.6 Power 49
- 9.5.7 Fault LED Out 49
- 9.5.8 Active LED Out 49
- 9.5.9 Enable port bypass signals 50
- 9.5.10 Motor start controls 50
- 9.5.11 SEL_6 through SEL_0 ID lines 50
- 9.6 Signal characteristics 52
- 9.1 FC-AL features 33
- 10.0 Seagate Technology support services 55
- List of Figures
- Figure 1. Barracuda 18FC family disc drive 1
- Figure 2. Barracuda 18FC disc drive 5
- Figure 3. Typical Barracuda 18FC drive +12V current profile 20
- Figure 4. Mounting configuration dimensions 23
- Figure 5. Physical interface 27
- Figure 6. LED indicator connector 28
- Figure 7. Air flow 29
- Figure 8. PCBA temperature measurement locations 30
- Figure 9. HDA case temperature measurement location 30
- Figure 10. Physical interface 46
- Figure 11. Port bypass circuit physical interconnect 46
- Figure 12. FC-AL SCA device connector dimensions 47
- Figure 13. J6 connector dimensions 47
- Figure 14. FC-AL transmitters and receivers 49
- Figure 15. Transmit eye diagram 53
- Figure 16. Receive eye diagram 53
- Contents
- 1.0 Scope
- 2.0 Applicable standards and reference documentation
- 3.0 General description
- 4.0 Performance characteristics
- 4.1 Internal drive characteristics
- 4.2 Seek performance characteristics
- 4.3 Start/stop time
- 4.4 Prefetch/multi-segmented cache control
- 4.5 Cache operation
- 1. Drive transfers to the initiator the first logical block requested plus all subsequent contigu...
- 2. When a requested logical block is reached that is not in any segment, the drive fetches it and...
- 3. The drive prefetches additional logical blocks contiguous to those transferred in step 2 above...
- 1. The drive fetches the requested logical blocks from the disc and transfers them into a segment...
- 2. The drive prefetches additional logical blocks contiguous to those transferred in Case A, step...
- 4.5.1 Caching write data
- 5.0 Reliability specifications
- 6.0 Physical/electrical specifications
- 6.1 AC power requirements
- 6.2 DC power requirements
- Table 1: DC power requirements
- [1] Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these ...
- [2] A –10% tolerance is allowed during initial spindle start but must return to ±5% before reachi...
- [3] See +12V current profile in Figure 3.
- [4] This condition occurs when the Motor Start option is enabled and the drive has not yet receiv...
- [5] See paragraph 6.2.1, “Conducted noise immunity.” Specified voltage tolerance includes ripple,...
- [6] Operating condition is defined as random seek reads of 64 blocks.
- [7] All power saving features enabled.
- [8] During idle, the heads are relocated every 60 seconds to a random location within the band fr...
- 1. Minimum current loading for each supply voltage is not less than 4% of the maximum operating c...
- 2. The +5V and +12V supplies should employ separate ground returns.
- 3. Where power is provided to multiple drives from a common supply, careful consideration for ind...
- 6.2.1 Conducted noise immunity
- 6.2.2 Power sequencing
- 6.2.3 Current profiles
- 6.3 Power dissipation
- 6.4 Environmental limits
- a. Operating
- b. Non-operating
- a. Operating
- b. Non-operating
- a. Operating
- b. Non-operating
- a. Operating (normal)
- b. Operating (abnormal)
- c. Non-operating
- d. Packaged
- a. Operating (normal)
- b. Operating (abnormal)
- c. Non-operating
- 7.0 Defect and error management
- 8.0 Installation
- 8.1 Drive ID/option selection
- 8.2 LED connections
- Figure 5. Physical interface
- [1] The drive has a 2.2K ohm resistor in series with this LED driver. Tie the minus side of an ex...
- [2] An external current-limiting resistor is required when connecting an LED to this pin. The min...
- [3] Jumper storage location (across pins 2 and 4).
- 8.2.1 J6 connector requirements
- 8.3 Drive orientation
- 8.4 Cooling
- 8.5 Drive mounting
- 8.6 Grounding
- 9.0 Interface requirements
- 9.1 FC-AL features
- No
- Yes
- Yes
- Yes
- Yes
- 00
- 04
- 05
- 9.1.4 Fibre Channel port login
- 9.1.5 Fibre Channel port login accept
- 9.1.6 Fibre Channel Process Login (PRLI)
- 9.1.7 Fibre Channel Process Accept (ACC)
- 9.1.8 Fibre Channel fabric login
- 9.1.9 Fibre Channel fabric accept login
- 9.1.10 Fibre Channel Arbitrated Loop options
- 9.2 Dual port support
- 9.3 SCSI commands supported
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- N
- N
- Y
- N
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- N
- Y
- Y
- Y
- N
- Y
- Y
- Y
- Y
- N
- Y
- Y
- Y
- N
- N
- N
- N
- N
- N
- Y
- N
- Y
- N
- N
- Y
- Y
- Y
- N
- Y
- N
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- N
- Y
- N
- N
- N
- Y
- Y
- N
- N
- N
- N
- N
- Y
- Y
- Y
- N
- Y
- N
- Y
- N
- Y
- Y
- N
- N
- N
- Y
- N
- N
- N
- [1] Barracuda 18FC drives can format to any multiple of four bytes per logical block in the range...
- [2] Warning. Power loss during flash programming can result in firmware corruption. This usually ...
- [3] Reference Mode Sense command 1Ah for mode pages supported.
- 9.3.1 Inquiry data
- 9.3.2 Mode Sense data
- A7
- 00
- 10
- 08
- 02
- 1E
- B3
- 90
- 00
- 00
- 02
- 00
- <------------------------------------------------ Mode sense pages data -------------------------...
- DEF
- 81
- 0A
- C0
- 0C
- E8
- 00
- 00
- 00
- 05
- 00
- FF
- FF
- CHG
- 81
- 0A
- FF
- FF
- 00
- 00
- 00
- 00
- FF
- 00
- FF
- FF
- DEF
- 82
- 0E
- 80
- 80
- 00
- 00
- 00
- 00
- 00
- 00
- 02
- 2B
- 00
- 00
- 00
- 00
- CHG
- 82
- 0E
- FF
- FF
- 00
- 00
- 00
- 00
- 00
- 00
- FF
- FF
- 00
- 00
- 00
- 00
- DEF
- 83
- 16
- 34
- 80
- 00
- 00
- 00
- 11
- 00
- 00
- 00
- ED
- 02
- 00
- 00
- 01
- 00
- 24
- 00
- 34
- 40
- 00
- 00
- 00
- CHG
- 83
- 16
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- DEF
- 84
- 16
- 00
- 1D
- 4D
- 14
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 1C
- 09
- 00
- 00
- CHG
- 84
- 16
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- DEF
- 87
- 0A
- 00
- 0C
- E8
- 00
- 00
- 00
- 00
- 00
- FF
- FF
- CHG
- 87
- 0A
- 0F
- FF
- 00
- 00
- 00
- 00
- 00
- 00
- FF
- FF
- DEF
- 88
- 12
- 10
- 00
- FF
- FF
- 00
- 00
- FF
- FF
- FF
- FF
- 80
- 03
- 00
- 00
- 00
- 00
- 00
- 00
- CHG
- 88
- 12
- B5
- 00
- 00
- 00
- FF
- FF
- FF
- FF
- 00
- 00
- A0
- FF
- 00
- 00
- 00
- 00
- 00
- 00
- DEF
- 8A
- 0A
- 02
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- CHG
- 8A
- 0A
- 03
- F1
- 08
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- DEF
- 99
- 06
- 00
- 00
- 00
- 00
- 00
- 00
- CHG
- 99
- 06
- 00
- 3F
- 00
- 00
- 00
- 00
- DEF
- 9A
- 0A
- 00
- 03
- 00
- 00
- 00
- 01
- 00
- 00
- 00
- 04
- CHG
- 9A
- 0A
- 00
- 03
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- DEF
- 9C
- 0A
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 01
- CHG
- 9C
- 0A
- 8D
- 0F
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- DEF
- 80
- 02
- 00
- 00
- CHG
- 80
- 02
- 37
- 40
- <--- Read capacity data --->
- 02
- 1E
- B3
- 8F
- 00
- 00
- 02
- 00
- Y
- Y
- N
- N
- Y
- N
- Y
- Y
- Y
- Y
- N
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- 9.5 FC-AL physical interface
- Figure 10. Physical interface
- 9.5.1 Physical characteristics
- 9.5.2 Connector requirements
- 9.5.3 Electrical description
- 9.5.4 Pin descriptions
- 9.5.5 FC-AL transmitters and receivers
- 9.5.6 Power
- 9.5.7 Fault LED Out
- 9.5.8 Active LED Out
- 9.5.9 Enable port bypass signals
- 9.5.10 Motor start controls
- 9.5.11 SEL_6 through SEL_0 ID lines
- 9.6 Signal characteristics
- 9.5 FC-AL physical interface
- 10.0 Seagate Technology support services

22 Barracuda 18FC Product Manual, Rev. B
mal levels may promote degraded operational performance during the abnormal shock period. Specified
operational performance will continue when normal operating shock levels resume. Shock may be applied
in the X, Y, or Z axis. Shock is not to be repeated more than two times per second.
c. Non-operating
The limits of non-operating shock apply to all conditions of handling and transportation. This includes both
isolated drives and integrated drives.
The drive subjected to non-repetitive shock not exceeding 75 Gs at a maximum duration of 11 msec (half
sinewave) will not exhibit device damage or performance degradation. Shock may be applied in the X, Y, or
Z axis.
The drive subjected to non-repetitive shock not exceeding 140 Gs at a maximum of 2 msec (half sinewave)
will not exhibit device damage or performance degradation. Shock may be applied in the X, Y, or Z axis.
d. Packaged
Disc drives shipped as loose load (not palletized) general freight will be packaged to withstand drops from
heights as defined in the table below. For additional details, refer to Seagate specifications 30190-001
(under 100 lbs/45 kg) or 30191-001 (over 100 lbs/45 kg).
6.4.4.2 Vibration
a. Operating (normal)
The drive as installed for normal operation will operate error free while subjected to continuous vibration not
exceeding:
5–350 Hz @ 0.5 G
Vibration may be applied on the X, Y, or Z axis.
b. Operating (abnormal)
Equipment as installed for normal operation will not incur physical damage while subjected to periodic vibra-
tion not exceeding:
15 minutes of duration at major resonant frequency
5–400 Hz @ 0.75 G
Vibration occuring at these levels may degrade operating performance during the abnormal vibration
period. Specified operating performance will continue when normal operating vibration levels are resumed.
This assumes system recovery routines are available. Abnormal vibration may be applied on the X, Y, or Z
axis.
c. Non-operating
The limits of non-operating vibration apply to all conditions of handling and transportation. This includes
both isolated drives and integrated drives.
The drive will not incur physical damage or degraded performance as a result of continuous vibration not
exceeding:
5–22 Hz @ 0.081 in. (2.05 mm) displacement
22–350 Hz @ 2.00 Gs
Vibration may be applied in the X, Y, or Z axis.
6.4.5 Air cleanliness
The drive is designed to operate in a typical office environment with minimal environmental control.
Package size Packaged/product weight Drop height
<600 cu in (<9,800 cu cm) Any 60 in (1,524 mm)
600 to 1,800 cu in (9,800 to 19,700 cu cm) 0 to 20 lb (0 to 9.1 kg) 48 in (1,219 mm)
>1,800 cu in (>19,700 cu cm) 0 to 20 lb (0 to 9.1 kg) 42 in (1,067 mm)
>600 cu in (>9,800 cu cm) 20 to 40 lb (9.1 to 18.1 kg) 36 in (914 mm)