Product manual
Table Of Contents
- Barracuda 18FC Disc Drive
- ST118273FC
- Product Manual, Volume 1
- Barracuda 18FC Disc Drive
- ST118273FC
- Product Manual, Volume 1
- Revision status summary sheet
- Contents
- 1.0 Scope 1
- 2.0 Applicable standards and reference documentation 3
- 3.0 General description 5
- 4.0 Performance characteristics 9
- 5.0 Reliability specifications 13
- 6.0 Physical/electrical specifications 19
- 7.0 Defect and error management 25
- 8.0 Installation 27
- 9.0 Interface requirements 33
- 9.1 FC-AL features 33
- 9.1.1 Fibre Channel link service frames 33
- 9.1.2 Fibre Channel task management functions 33
- 9.1.3 Fibre Channel task management responses 33
- 9.1.4 Fibre Channel port login 34
- 9.1.5 Fibre Channel port login accept 35
- 9.1.6 Fibre Channel Process Login (PRLI) 35
- 9.1.7 Fibre Channel Process Accept (ACC) 35
- 9.1.8 Fibre Channel fabric login 36
- 9.1.9 Fibre Channel fabric accept login 37
- 9.1.10 Fibre Channel Arbitrated Loop options 38
- 9.2 Dual port support 38
- 9.3 SCSI commands supported 39
- 9.4 Miscellaneous operating features and conditions 45
- 9.5 FC-AL physical interface 46
- 9.5.1 Physical characteristics 46
- 9.5.2 Connector requirements 47
- 9.5.3 Electrical description 48
- 9.5.4 Pin descriptions 48
- 9.5.5 FC-AL transmitters and receivers 49
- 9.5.6 Power 49
- 9.5.7 Fault LED Out 49
- 9.5.8 Active LED Out 49
- 9.5.9 Enable port bypass signals 50
- 9.5.10 Motor start controls 50
- 9.5.11 SEL_6 through SEL_0 ID lines 50
- 9.6 Signal characteristics 52
- 9.1 FC-AL features 33
- 10.0 Seagate Technology support services 55
- List of Figures
- Figure 1. Barracuda 18FC family disc drive 1
- Figure 2. Barracuda 18FC disc drive 5
- Figure 3. Typical Barracuda 18FC drive +12V current profile 20
- Figure 4. Mounting configuration dimensions 23
- Figure 5. Physical interface 27
- Figure 6. LED indicator connector 28
- Figure 7. Air flow 29
- Figure 8. PCBA temperature measurement locations 30
- Figure 9. HDA case temperature measurement location 30
- Figure 10. Physical interface 46
- Figure 11. Port bypass circuit physical interconnect 46
- Figure 12. FC-AL SCA device connector dimensions 47
- Figure 13. J6 connector dimensions 47
- Figure 14. FC-AL transmitters and receivers 49
- Figure 15. Transmit eye diagram 53
- Figure 16. Receive eye diagram 53
- Contents
- 1.0 Scope
- 2.0 Applicable standards and reference documentation
- 3.0 General description
- 4.0 Performance characteristics
- 4.1 Internal drive characteristics
- 4.2 Seek performance characteristics
- 4.3 Start/stop time
- 4.4 Prefetch/multi-segmented cache control
- 4.5 Cache operation
- 1. Drive transfers to the initiator the first logical block requested plus all subsequent contigu...
- 2. When a requested logical block is reached that is not in any segment, the drive fetches it and...
- 3. The drive prefetches additional logical blocks contiguous to those transferred in step 2 above...
- 1. The drive fetches the requested logical blocks from the disc and transfers them into a segment...
- 2. The drive prefetches additional logical blocks contiguous to those transferred in Case A, step...
- 4.5.1 Caching write data
- 5.0 Reliability specifications
- 6.0 Physical/electrical specifications
- 6.1 AC power requirements
- 6.2 DC power requirements
- Table 1: DC power requirements
- [1] Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these ...
- [2] A –10% tolerance is allowed during initial spindle start but must return to ±5% before reachi...
- [3] See +12V current profile in Figure 3.
- [4] This condition occurs when the Motor Start option is enabled and the drive has not yet receiv...
- [5] See paragraph 6.2.1, “Conducted noise immunity.” Specified voltage tolerance includes ripple,...
- [6] Operating condition is defined as random seek reads of 64 blocks.
- [7] All power saving features enabled.
- [8] During idle, the heads are relocated every 60 seconds to a random location within the band fr...
- 1. Minimum current loading for each supply voltage is not less than 4% of the maximum operating c...
- 2. The +5V and +12V supplies should employ separate ground returns.
- 3. Where power is provided to multiple drives from a common supply, careful consideration for ind...
- 6.2.1 Conducted noise immunity
- 6.2.2 Power sequencing
- 6.2.3 Current profiles
- 6.3 Power dissipation
- 6.4 Environmental limits
- a. Operating
- b. Non-operating
- a. Operating
- b. Non-operating
- a. Operating
- b. Non-operating
- a. Operating (normal)
- b. Operating (abnormal)
- c. Non-operating
- d. Packaged
- a. Operating (normal)
- b. Operating (abnormal)
- c. Non-operating
- 7.0 Defect and error management
- 8.0 Installation
- 8.1 Drive ID/option selection
- 8.2 LED connections
- Figure 5. Physical interface
- [1] The drive has a 2.2K ohm resistor in series with this LED driver. Tie the minus side of an ex...
- [2] An external current-limiting resistor is required when connecting an LED to this pin. The min...
- [3] Jumper storage location (across pins 2 and 4).
- 8.2.1 J6 connector requirements
- 8.3 Drive orientation
- 8.4 Cooling
- 8.5 Drive mounting
- 8.6 Grounding
- 9.0 Interface requirements
- 9.1 FC-AL features
- No
- Yes
- Yes
- Yes
- Yes
- 00
- 04
- 05
- 9.1.4 Fibre Channel port login
- 9.1.5 Fibre Channel port login accept
- 9.1.6 Fibre Channel Process Login (PRLI)
- 9.1.7 Fibre Channel Process Accept (ACC)
- 9.1.8 Fibre Channel fabric login
- 9.1.9 Fibre Channel fabric accept login
- 9.1.10 Fibre Channel Arbitrated Loop options
- 9.2 Dual port support
- 9.3 SCSI commands supported
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- N
- N
- Y
- N
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- N
- Y
- Y
- Y
- N
- Y
- Y
- Y
- Y
- N
- Y
- Y
- Y
- N
- N
- N
- N
- N
- N
- Y
- N
- Y
- N
- N
- Y
- Y
- Y
- N
- Y
- N
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- N
- Y
- N
- N
- N
- Y
- Y
- N
- N
- N
- N
- N
- Y
- Y
- Y
- N
- Y
- N
- Y
- N
- Y
- Y
- N
- N
- N
- Y
- N
- N
- N
- [1] Barracuda 18FC drives can format to any multiple of four bytes per logical block in the range...
- [2] Warning. Power loss during flash programming can result in firmware corruption. This usually ...
- [3] Reference Mode Sense command 1Ah for mode pages supported.
- 9.3.1 Inquiry data
- 9.3.2 Mode Sense data
- A7
- 00
- 10
- 08
- 02
- 1E
- B3
- 90
- 00
- 00
- 02
- 00
- <------------------------------------------------ Mode sense pages data -------------------------...
- DEF
- 81
- 0A
- C0
- 0C
- E8
- 00
- 00
- 00
- 05
- 00
- FF
- FF
- CHG
- 81
- 0A
- FF
- FF
- 00
- 00
- 00
- 00
- FF
- 00
- FF
- FF
- DEF
- 82
- 0E
- 80
- 80
- 00
- 00
- 00
- 00
- 00
- 00
- 02
- 2B
- 00
- 00
- 00
- 00
- CHG
- 82
- 0E
- FF
- FF
- 00
- 00
- 00
- 00
- 00
- 00
- FF
- FF
- 00
- 00
- 00
- 00
- DEF
- 83
- 16
- 34
- 80
- 00
- 00
- 00
- 11
- 00
- 00
- 00
- ED
- 02
- 00
- 00
- 01
- 00
- 24
- 00
- 34
- 40
- 00
- 00
- 00
- CHG
- 83
- 16
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- DEF
- 84
- 16
- 00
- 1D
- 4D
- 14
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 1C
- 09
- 00
- 00
- CHG
- 84
- 16
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- DEF
- 87
- 0A
- 00
- 0C
- E8
- 00
- 00
- 00
- 00
- 00
- FF
- FF
- CHG
- 87
- 0A
- 0F
- FF
- 00
- 00
- 00
- 00
- 00
- 00
- FF
- FF
- DEF
- 88
- 12
- 10
- 00
- FF
- FF
- 00
- 00
- FF
- FF
- FF
- FF
- 80
- 03
- 00
- 00
- 00
- 00
- 00
- 00
- CHG
- 88
- 12
- B5
- 00
- 00
- 00
- FF
- FF
- FF
- FF
- 00
- 00
- A0
- FF
- 00
- 00
- 00
- 00
- 00
- 00
- DEF
- 8A
- 0A
- 02
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- CHG
- 8A
- 0A
- 03
- F1
- 08
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- DEF
- 99
- 06
- 00
- 00
- 00
- 00
- 00
- 00
- CHG
- 99
- 06
- 00
- 3F
- 00
- 00
- 00
- 00
- DEF
- 9A
- 0A
- 00
- 03
- 00
- 00
- 00
- 01
- 00
- 00
- 00
- 04
- CHG
- 9A
- 0A
- 00
- 03
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- DEF
- 9C
- 0A
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 01
- CHG
- 9C
- 0A
- 8D
- 0F
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- 00
- DEF
- 80
- 02
- 00
- 00
- CHG
- 80
- 02
- 37
- 40
- <--- Read capacity data --->
- 02
- 1E
- B3
- 8F
- 00
- 00
- 02
- 00
- Y
- Y
- N
- N
- Y
- N
- Y
- Y
- Y
- Y
- N
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- Y
- 9.5 FC-AL physical interface
- Figure 10. Physical interface
- 9.5.1 Physical characteristics
- 9.5.2 Connector requirements
- 9.5.3 Electrical description
- 9.5.4 Pin descriptions
- 9.5.5 FC-AL transmitters and receivers
- 9.5.6 Power
- 9.5.7 Fault LED Out
- 9.5.8 Active LED Out
- 9.5.9 Enable port bypass signals
- 9.5.10 Motor start controls
- 9.5.11 SEL_6 through SEL_0 ID lines
- 9.6 Signal characteristics
- 9.5 FC-AL physical interface
- 10.0 Seagate Technology support services

Barracuda 18FC Product Manual, Rev. B 63
Q
queue tagging 45
R
radiated emissions 31
radio interference regulations 3
Random relative offset 34, 37
RCD bit 11
Read buffer command 40
Read capacity command 40
Read combined header and data mode (0) 40
Read command 39
Read data mode (2) 40
Read defect data command 40
Read descriptor mode (3) 40
Read extended command 40
Read Link Status (RLS) 33
Read long command 40
read/write data heads 9
Reassign blocks command 39
Receive buffer field size 34, 37
receive buffer field size 35
Receive diagnostic results command 39
receive eye
diagram 53
receivers 49
recovered error (1h) 13
reference
components 30
documents 4
Regenerate command 41
Relative address command 40
Release command 39
Released (10) command 41
reliability 7
and service 15
specifications 13
repair and return information 17
reporting actual retry count 45
Request sense command 39
reservation conflict status 45
Reserve command 39
Reserved (10) command 41
return information 17
Rezero unit command 39
Rigid disc drive geometry page
command 39
rotation speed 9
running disparity 17
S
safety 3
SCA part numbers 47
SCSI interface
commands supported 39
SCSI Interface Product Manual 3
Search data
equal command 40
high command 40
low command 40
Seek command 39
seek error
defined 13
rate 13
Seek extended command 40
seek performance characteristics 9
seek positioning error (15h) 13
seek time
average typical 9
full stroke typical 9
single track typical 9
segmented caching 45
SEL ID 27
lines 50
standard feature 6
Self-Monitoring Analysis and Reporting Technology
7, 14
Send diagnostics page command 40
Sequential delivery 34, 37
service
life 13, 16
philosophy 16
tools 16
Service Options 37
Service options 34
servo
DSP, case temperature 30
Set limits command 40
shielding 3
shipping 16
shock limits 21
non-operating 22
operating (abnormal) 21
operating (normal) 21
packaged 22
signal
characteristics 52
ground 31
LED driver 52
single-unit shipping pack kit 7
SMART 7, 14
SMP = 1 in Mode Select command 45
SO 34, 37
spindle brake 6
Stacked connection req. 34, 37
standards 3
Start unit/stop unit command 39
start/stop time 10
support services 55
Supported diagnostics pages command 39, 40
surface stiffness
allowable for non-flat surface 31
switches 27
Synchronize cache command 40










