User guide

Introduction
11
1.5.4 Power Cord
(minimum requirements)
1.5.5 Environment
Operational & Peak Currents 6.5A @ 110V,
10.5A Peak @ 110V
6.5A @ 110V,
10.5A Peak @ 110V
Inrush Current 40/80A @ 110/220VAC
(25º cold start 1 PSU)
50A @ 260VAC
Power Factor <0.6 >0.95
Usage PSU Types must not be inter-mixed
Harmonics N/A Meets IEC 60555-2
Cord Type SV 0r SVT, 18 AWG minimum, 3 conductor
Plug 250V, 10A
Socket IEC 320, 250V, 10A
Table 1–3 Ambient Temperature and Humidity
Temperature Range Relative Humidity Max. Wet Bulb
Operational 10°C to 40°C
(35°C if only 1 PSU/
Cooling Module)
20% to 80%
non-condensing
23°C
Non-Operational 0°C to +60°C 8% to 80%
non-condensing
Shipping -20°C to +60°C 5% to 100%
non-precipitating
Altitude 0 to 2133 m
Operational Shock Vertical axis 5g peak 1/2 sine, 10ms
Operational Vibration Random vibration power spectrum available on request
Non-Operational Shock 20g 20ms square wave
Acoustics Free standing enclosure declared ‘A’ weighted sound power level 6.8
Bels
Orientation & Mounting 19" Rack mount (4EIA Units)
Rack Rails To fit 800mm depth Racks compliant with IEC 297
Rack Characteristics Back pressure not exceeding 5 pascals (0.5mm water gauge)
Safety & Approvals CE, UL, cUL
EMC EN55022 (CISPR - A), FCC A