User guide

Operation
37
Under Normal conditions the LEDs should all be illuminated constant GREEN
If a problem is detected the ESI processor will change the color of the relevant LED to AMBER.
For non critical conditions the LEDs flash GREEN.
Refer to Chapter 4, ”Troubleshooting and Problem Solving” for details of any fault indication.
3.4 Starting the Drives
Unless otherwise selected during installation, all drives in the enclosure should automatically start their motors in a
delayed sequence after power is applied. If this has not occurred one of the following conditions may exist.
The disk drive DIL switch has been set in the ESI/Ops panel module during installation, thus disabling the
drive auto start function. If manual start has been selected, then Drive Start commands must be issued to each
drive in order to start their motors
There is a power problem (an alarm and power fault indication would normally be active).
3.4.1 Disk Drives LEDs
Each drive carrier incorporates two indicators, an upper (GREEN) and lower (AMBER). In normal operation the
Green LED will be ON and will flicker as the drive operates.
3.5 Power Down
To power the enclosure down,
either
Place the Enclosure in STANDBY Mode (See Service Mode operation above).
or