User manual

any time.
Yield – Temporary pause while a read/write operation takes
place.
Paused– Temporary pause while another background runs.
Or a pause initiated by the user.
Redundancy Check:
Redundancy Check is a routine maintenance Procedure for
fault-tolerant disk arrays (those with redundancy) that
ensures all the data matches exactly. Redundancy Check
can also correct inconsistencies.
Rebuild:
When you rebuild a disk array, you are actually rebuilding
the data on one physical drive.
When a physical drive in a disk array fails and a spare drive
of adequate capacity is available, the disk array begins to
rebuild automatically using the spare drive.
If there is no spare drive of adequate capacity, but the Auto
Rebuild function is ENABLED, the disk array begins to
rebuild automatically as soon as you remove the failed
physical drive and install an un-configured physical drive in
the same slot.
If there is no spare drive of adequate capacity and the Auto
Rebuild function is DISABLED, you must replace the failed
drive with an un-configured physical drive, then perform a
Manual Rebuild. See below.
IMPORTANT: IF YOUR REPLACEMENT DISK DRIVE WAS FORMERLY
PART OF A DIFFERENT DISK ARRAY OR LOGICAL DRIVE, YOU MUST
CLEAR THE CONFIGURATION DATA ON THE
REPLACEMENT DRIVE
BEFORE YOU USE IT.
55