Specifications

Hawk 2XL Product Manual, Rev. B 25
6.4.4.2 Vibration
a. Operating
The drive as installed for normal operation, shall comply with the complete specified performance while
subjected to continuous vibration not exceeding
5-22 Hz @ 0.020 inches (0.51 mm) displacement
22-400 Hz @ 0.5 g
Vibration may be applied in the X, Y, or Z axis.
b. Non-operating
The limits of non-operating vibration shall apply to all conditions of handling and transportation. This
includes both isolated drives and integrated drives.
The drive shall not incur physical damage or degraded performance as a result of continuous vibration not
exceeding
5-22 Hz @ 0.081 inches (2.05 mm) displacement
22-400 Hz @ 2.00 g
Vibration may be applied in the X, Y, or Z axis.
6.4.5 Air cleanliness
The drive is designed to operate in a typical office environment with minimal environmental control.
6.4.6 Electromagnetic susceptibility
See Section 2.1.2.