Product manual

1.8.4 Relative humidity
Operating 8% to 80% noncondensing
Maximum wet bulb 29.C (84.9°F)
Operating gradient, max 10% per hour
Nonoperating 5% to 95% noncondensing
Maximum wet bulb 35°C (95.F)
1.9 Shock and vibration
All shock and vibration specifications assume that the inputs are measured
at the drive mounting screws. Shock measurements are based on an
11-msec, half sine wave shock pulse, not to be repeated more than twice
per second.
During normal operating shock and vibration, there is no physical dam-
age to the drive or performance degradation.
During abnormal operating shock and vibration, there is no physical
damage to the drive, although performance may be degraded during the
shock or vibration episode. When normal operating shock levels resume,
the drive meets its performance specifications.
During nonoperating shock and vibration, the read/write heads are
positioned in the shipping zone.
Normal
operating
Abnormal
operating
Nonoperating
Shock 2 Gs 10 Gs 75 Gs
5–22 Hz vibration 0.020-inch
displacement
0.030-inch
displacement
0.160-inch
displacement
22–350 Hz vibration 0.50 Gs 0.75 Gs 4.00 Gs
1.10 Acoustics
Sound pressure is measured at idle from 1 meter above the drive top
cover.
Idle Seek
Sound pressure, typ 30 dBA 34 dBA
Sound pressure, max 34 dBA 38 dBA