Product manual

Notes:
1.
The Supplied Format field specifies the format of the address
to translate field. The valid values for this field are 000 for
logical block address format or 101 for physical sector address
format. If the drive does not support the requested format it
terminates the Send Diagnostic command with a Check Con-
dition status. The sense key is set to Illegal Request and an
additional sense code is set to Invalid Field in the Parameter
List.
2.
The Translate Format field specifies the format to which the
initiator wants the address to be translated. The valid values
for this field are 000 for logical block address format or 101 for
physical sector address format. The Translate Format field
must be different than the Supplied Format field. If the drive
does not support the requested format it terminates the com-
mand with a Check Condition status. The sense key is set to
Illegal Request and an additional sense code is set to Invalid
Field in Parameter List.
3.
The Address to Translate field contains a single address that
the initiator is requesting the drive to translate. The format of
this field is defined by the Supplied Format field.
For systems that support disconnection, the drive disconnects
while executing this command.
3.6.1 Read Capacity command (25
H
)
The initiator uses the Read Capacity command to determine the capacity
of the drive. When the drive receives the Read Capacity command, it
sends the initiator read capacity data, which is described in Section
3.6.1.1. on page 64.
Bytes
Bits
7654321 0
0 0010010 1
1 LUN 0000 0
2–5 Logical block address
6 0000000 0
7 0000000 0
8 0000000PMI
9 0000000 0
Medalist Pro 2160N/2160WC Product Manual, Rev. A 63