Product manual

length value that causes the parameter value to truncate,
the drive terminates the command with a Check Condition
status. The sense key is set to Illegal Request with addi-
tional sense code set to Invalid Field Parameter List.
BByte 4
The
parameter value
field uses 1, 2, 4 or 8 bytes to transmit
an unsigned counter value. The initiator sends counts to
set values into counters in the drive, and the drive returns
counter values to the initiator. The initiator is responsible for
issuing a Log Sense command to learn the parameter
length the drive has selected.
3.8 Log Sense command (4D
H
)
The Log Sense command (4D
H
) provides a means for an initiator
to manage the statistical data maintained by the drive about drive
operation. Initiators that implement the Log Select command
also implement the Log Sense command.
82 Medalist Pro 2160N/2160WC Product Manual, Rev. A