User Manual

Seagate SkyHawk Serial ATA Product Manual, Rev. B 15
www.seagate.com Drive specifications
1.2.6.2 Shock
All shock specifications assume that the drive is mounted securely with the input shock applied at the drive mounting
screws. Shock may be applied in the X, Y or Z axis.
1.2.6.2.1 Operating shock
These drives comply with the performance levels specified in this document when subjected to a maximum operating
shock of 70 Gs (read) and 40 Gs (write) based on half-sine shock pulses of 2ms. Shocks should not be repeated more
than two times per second.
1.2.6.2.2 Nonoperating shock
The nonoperating shock level that the drive can experience without incurring physical damage or degradation in
performance when subsequently put into operation is 250 Gs based on a nonrepetitive half-sine shock pulse of 2ms
duration.
1.2.6.3 Vibration
All vibration specifications assume that the drive is mounted securely with the input vibration applied at the drive
mounting screws. Vibration may be applied in the X, Y or Z axis.
1.2.6.3.1 Operating vibration
The maximum vibration levels that the drive may experience while meeting the performance standards specified in
this document are specified below.
* Rotary Random Operating Vibration
1.2.6.3.2 Nonoperating vibration
The maximum nonoperating vibration levels that the drive may experience without incurring physical damage or
degradation in performance when subsequently put into operation are specified below.
.
5–22 Hz 0.25 Gs
22–350 Hz 0.50 Gs
350–500 Hz 0.25 Gs
20 - 1500Hz
*(RROV)
12.5 rads/s
2
w/RVFF
2–500 Hz
Linear Random
2.27 Grms ref
Freq (Hz) 2 4 100 500
G
2
/Hz .001 .03 .03 .001