KZPSA PCI-to-SCSI Storage Adapter User's Guide Order Number: EK–KZPSA–UG.
Second Printing, April 1995 While Digital believes the information included in this publication is correct as of the date of publication, it is subject to change without notice. Digital Equipment Corporation assumes no responsibility for any errors that might appear in this document.
Contents 1 Product Description 1.1 Introduction................................................................................................. 1–1 1.2 Standards..................................................................................................... 1–4 1.3 Specifications.............................................................................................. 1–4 2 Configuration Guidelines 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 3 Configuration Defaults.........................
KZPSA PCI-to-SCSI Storage Adapter 5 Windows NT AXP Systems 5.1 Software Supplied.......................................................................................5–1 5.2 Completing the KZPSA Installation............................................................5–1 5.3 Installing the Device Driver........................................................................5–3 6 KZPSA Adapter Utilities 6.1 General Overview..................................................................................
Contents Figures 1–1 2–1 3–1 3–2 6–1 6–2 6–3 6–4 6–5 6–6 6–7 6–8 B–1 B–2 B–3 KZPSA PCI-to-SCSI Storage Adapter........................................................ 1–1 KZPSA Termination Resistor Locations..................................................... 2–3 Typical KZPSA Installations...................................................................... 3–3 Connecting SCSI Cable.............................................................................. 3–5 Initial Screen.........................
Revision Record This Revision Record provides a concise publication history of this guide. It lists the guide revision levels, release dates, and reasons for the revisions. It also describes how the changes to affected pages are marked in the guide. The following revision history lists all revisions of this publication and their effective dates. The publication part number is included in the Revision Level column, with the last entry denoting the latest revision.
About This Guide This section identifies the audience of this guide and describes the contents (chapter-bychapter) and structure. In addition, this section includes a list of associated documents and the conventions used in this guide.
KZPSA PCI-to-SCSI Storage Adapter Chapter 3: Installing the KZPSA Adapter Installing the KZPSA PCI-to-SCSI Storage Adapter describes how to physically install the KZPSA adapter board into a computer. It provides unpacking and hardware installation information. Chapter 4: OpenVMS AXP and OSF/1 Systems OpenVMS AXP and OSF/1 Systems provides specific information to install and use the KZPSA adapter with either the OpenVMS AXP or OSF/1 operating systems.
About This Guide Appendix B: Sample KZPSA Adapter Configurations Sample KZPSA Adapter Configurations describes three possible configurations in which differential and single-ended SCSI devices, housed within a storage enclosure and external to the host system, are interconnected by way of the KZPSA adapter's external SCSI port connector.
1 Product Description This chapter provides a product description of the KZPSA PCI-to-SCSI Storage Adapter. It also lists the operating standards for the adapter and its electrical and environmental specifications. 1.1 Introduction The KZPSA adapter (Figure 1–1) is a Peripheral Component Interconnect (PCI) to Small Computer System Interface-2 (SCSI-2) adapter. You install the adapter on your computer motherboard through a PCI connector for 32 bit/+5V operation.
KZPSA PCI-to-SCSI Storage Adapter The adapter’s processor minimizes the SCSI I/O overhead of the host computer’s processor by interpreting host commands and translating them into specific device commands. This includes support for direct data transfer to host memory, coding device-specific commands into specific command scripts, and supporting internal command queues with disconnect/reconnect functionality.
Chapter 1.
KZPSA PCI-to-SCSI Storage Adapter 1.2 Standards The KZPSA adapter conforms to the Standards listed in Table 1–1. Table 1–1 Standards Industry Standard 1.3 Description SCSI-2 ANSI X3T9.2/86-109 - SCSI Specification. PCI PCI Local Bus Specification Rev 2.0. FCC Class B Residential use. Specifications The electrical and environmental specifications for the KZPSA adapter are listed in Table 1–2.
2 Configuration Guidelines Before you install the KZPSA PCI-to-SCSI storage adapter in your computer, you need to become familiar with the configuration guidelines for the host adapter and its SCSI bus. This chapter will help you plan your system configuration. It discusses the SCSI bus configuration, bus termination and power, and describes bus signals and their functions. 2.
KZPSA PCI-to-SCSI Storage Adapter These defaults were chosen for optimum performance of the adapter. If they are acceptable for your configuration, proceed to Installation in Chapter 3. Each of these attributes, except for termination present, can be changed by using the configuration utility described in Chapter 6. 2.2 PCI Bus Configuration PCI Adapters are automatically configured by the power-up software. The adapter addresses and interrupts are set without jumpers. 2.
Chapter 2. Configuration Guidelines 2.4 SCSI Bus Termination Bus termination is required at each end of the SCSI bus. Typically, the SCSI bus has the KZPSA adapter at one end and some storage device at the other end. In this case, you must have termination resistor packs (Z1–Z5, Figure 2–1) installed in the KZPSA adapter; these are installed at the factory. There should not be any termination at any of the intermediate devices.
KZPSA PCI-to-SCSI Storage Adapter 2.5 SCSI Termination Power It is normal for adapters, not devices, to supply termination power to the SCSI bus. The KZPSA adapter is configured at the factory to supply 1.5 amps of termination current. Although each SCSI node may supply termination power to the bus, a single source from the host adapter is sufficient. No more than four sources of termination power on a SCSI bus is recommended. 2.
Chapter 2. Configuration Guidelines 2.11 Device Disconnects To optimize overall SCSI bus performance, the adapter default allows device disconnects. This means that a device that realizes a need for a lengthy delay before the next data can be transferred can disconnect this operation to allow another device to utilize the bus, and resume it later when the data is available. This disconnect may also be disabled when there is only a single device on the bus.
3 Installing the KZPSA Adapter This chapter describes how to install the KZPSA adapter board into a computer. 3.1 Unpacking Unpack the KZPSA PCI-to-SCSI Storage Adapter kit and place the contents (board, diskettes, etc.) in an area where they are protected and accessible for installation. Perform an inventory of the contents.
KZPSA PCI-to-SCSI Storage Adapter 3.2 Hardware Installation Procedure CAUTION Static electricity can destroy the circuits on the KZPSA adapter. Discharge static electricity by touching the system box's metal frame before handling the KZPSA module or any other modules. 1. Power down your computer and remove the covers to access the motherboard. Refer to your host system manual for general instructions on installing adapters.
Chapter 3. Installing the KZPSA Adapter Figure 3–1 Typical KZPSA Installations With factory-installed metal extender guide. With alternate metal extender guide. EK–KZPSA–UG.
KZPSA PCI-to-SCSI Storage Adapter Figure 3–1 Typical KZPSA Installations (continued) With alternate plastic extender guide. 3–4 EK–KZPSA–UG.
Chapter 3. Installing the KZPSA Adapter Figure 3–2 Connecting SCSI Cable EK–KZPSA–UG.
4 OpenVMS AXP and OSF/1 Systems This chapter provides information which is unique to the installation and use of your KZPSA adapter with either the OpenVMS AXP or OSF/1 operating systems. The information includes how to verify the physical installation of the adapter in your system and how to modify some adapter parameters for the console. Some adapter parameters require the use of KZPSA utilities as described in Chapter 6. 4.
KZPSA PCI-to-SCSI Storage Adapter If there is an error, try system power-on again. If the KZPSA error persists, refer to Chapter 7, Troubleshooting. NOTE If the KZPSA passes self-test, no message is displayed at console boot. Enter "show config" at the console prompt to see if the devices on the KZPSA SCSI bus can be accessed. This command displays the system configuration as determined by the SRM console during power-up (Refer to your AXP Systems Documentation.
Chapter 4. OpenVMS AXP and OSF/1 Systems 4.4 KZPSA SCSI ID The SCSI ID of the KZPSA adapter is set by default to 7. If you want to change it, enter the console command as follows: set pk*0_host_id # where: * is the controller ID from show config and # is the SCSI_id (0-7) 4.5 SCSI Termination Power The KZPSA adapter supplies SCSI termination power by default.
KZPSA PCI-to-SCSI Storage Adapter 4.7 KZPSA Device Booting The SRM console can be used to set a default device, such as a device on the KZPSA SCSI bus, to boot the operating system. To boot the operating system from a device on the KZPSA adapter, define the default boot device at the console as follows: set bootdef_dev device_name where: device_name = name of your boot device which is identified with the show "config" or "show device" command. 4–4 EK–KZPSA–UG.
5 Windows NT AXP Systems This chapter provides information which is unique to the installation and use of your KZPSA adapter with the Windows NT AXP operating system. The information includes how to verify the physical installation of the KZPSA adapter in your system, and how to install the KZPSA driver software in Windows NT. Refer to Chapter 6 for a description of the KZPSA Adapter Utilities needed to perform the KZPSA adapter configuration and firmware installation. 5.
KZPSA PCI-to-SCSI Storage Adapter 2. Power up your system; the Alpha AXP should go through its start up sequence and then display the ARC Boot Menu on your display terminal. Typically, your display should look like the following: (Several lines of menu choices are displayed here) If you do not see this menu, refer to your system documentation for more information about initially setting up your Alpha AXP. Return to this procedure when you have the Boot Menu displayed. 3.
Chapter 5. Windows NT AXP Systems 6. Note that the third line in the list contains a Vendor Id field of “1011” and a device type of “8”. These two values uniquely identify the KZPSA. Search your display for a line (or lines if you installed more than one KZPSA) containing these exact values. If there is no entry that corresponds to the KZPSA, your adapter may not be correctly installed. Power off your system and repeat the installation process in Chapter 3 of this guide, then this procedure.
KZPSA PCI-to-SCSI Storage Adapter 8. Insert the diskette labeled KZPSA Alpha AXP Software into the floppy drive. The prompt “a:\” is displayed for the default drive. 9. Click on OK at the prompt. 10. The name of the driver (DECKZPSA.SYS) is displayed. Click on OK. 11. The Select Adapter Option box displays the name of the adapter (DECKZPSA). Click on the Install button. 12. The Windows NT Setup dialog box displays the path information from step 8 above.
6 KZPSA Adapter Utilities This chapter describes the KZPSA Adapter Utilities. It describes how to run the Configuration and Diagnostic Utility and the Firmware Update Utility. 6.1 General Overview Two of the KZPSA Utilities run from the ARC console. After you power up your system, the Alpha AXP should go through its start up sequence and then display the ARC Boot Menu on your display terminal.
KZPSA PCI-to-SCSI Storage Adapter NOTE Refer to the Release Notes for the minimum revision levels of the ARC firmware. Select Run a program from the Boot menu. Place the utilities diskette into the floppy drive. If you want to invoke the configuration/diagnostic utility, type a:\cnfgdiag.exe at the “Program to run” prompt. If you want to invoke the firmware update utility, type a:\fwupdate.exe at the “Program to run” prompt. 6.
Chapter 6.
KZPSA PCI-to-SCSI Storage Adapter Figure 6–1 Initial Screen Use the arrow keys to select the KZPSA you wish to configure or test. Once selected, press Enter to proceed to the Options Window (Figure 6–2). 6–4 EK–KZPSA–UG.
Chapter 6. KZPSA Adapter Utilities Figure 6–2 Options Use the arrow keys to select the option you wish to proceed with. You can select the following: • SCSI options This allows the user to see devices connected to the KZPSA and modify parameters associated with them. It also allows users to configure SCSI parameters such as fast SCSI mode, supply termpower from the KZPSA, tagged command queuing, and SCSI reset on boot. The user can also reset the SCSI bus from SCSI options.
KZPSA PCI-to-SCSI Storage Adapter Figure 6–3 SCSI Options Use the arrow keys to select the following: • List existing SCSI devices • Configure device specific parameters • Reset the SCSI bus These functions are described in detail in Chapter 2.
Chapter 6. KZPSA Adapter Utilities Figure 6–4 Configuring Device Specific Parameters Use the arrow keys to move through the device and parameter choices. Use the spacebar to toggle between YES and NO. Select Save and Exit to save parameter modifications. Select Use Default Setting to return to the factory default settings.
KZPSA PCI-to-SCSI Storage Adapter Figure 6–5 Diagnostics The user can run the Power-On Self Test (POST) or SCSI Device Self Tests. Use the spacebar to toggle the Diagnostic Test from Power-On Self Test to SCSI Device Self Test. Press the down arrow key to select the Error Action. Use the spacebar to toggle through to possible error actions. The possible error actions are: Halt on Error The diagnostic test stops when an error occurs.
Chapter 6. KZPSA Adapter Utilities Figure 6–6 Error Log Example EK–KZPSA–UG.
KZPSA PCI-to-SCSI Storage Adapter 6.3 Firmware Update Utility NOTE The KZPSA firmware requires approximately one minute to load in the following procedure. The KZPSA firmware can be loaded via the firmware update utility (fwupdate.exe). It allows the user to change the firmware without replacing the physical ROM. The first screen of the firmware update utility is shown in Figure 6–7.
Chapter 6. KZPSA Adapter Utilities Figure 6–8 Firmware Update Utility Pressing Enter initiates the firmware update process. Pressing the Esc key aborts the update. Reset your system after a successful firmware update for new firmware to take effect. EK–KZPSA–UG.
7 Troubleshooting This chapter provides troubleshooting information to help diagnose problems that can occur during the installation of the KZPSA adapter. If you experience difficulty in installing or verifying the operation of the adapter, refer to the information in the troubleshooting tables to isolate and diagnose the problem. 7.1 Introduction Troubleshooting is the process of isolating and diagnosing problems.
KZPSA PCI-to-SCSI Host Adapter 7.2 System Power-on Problems After you turn on your host system, the CPU either performs a series of self-tests or enters the console mode. Table 7–1 describes possible problems that could occur during self-tests, specifies their probable cause, and provides corrective action. Table 7–1 Power-on Problems Troubleshooting Table 7–2 Symptom Probable Cause Corrective Action System self-tests halt with error message or error summary displayed on console terminal.
Chapter 7. Troubleshooting 7.3 SCSI Device Problems Table 7–2 lists a SCSI device problem, specifies the probable causes, and suggests corrective actions for each probable cause. Table 7–2 SCSI Device Troubleshooting Table Symptom Probable Cause Corrective Action SCSI device does not appear in the configuration display after the SRM console command, Device cannot negotiate wide or synchronous transfers. Use the cnfgdiag utility to disable (see Chapter 6).
KZPSA PCI-to-SCSI Host Adapter Table 7–2 SCSI Device Troubleshooting Table (Continued) Symptom Probable Cause Corrective Action SCSI device does not . . . SCSI bus not terminated properly. Ensure each end of the bus is terminated. Total length of SCSI bus too long. Check total length of SCSI bus as follows: Fast Single-ended, 3 meters, maximum. Slow single-ended, 6 meters, maximum. Fast differential, 25 meters, maximum. Defective SCSI device. 7–4 Replace SCSI device. EK–KZPSA–UG.
Chapter 7. Troubleshooting 7.4 Boot Sequence Problems Table 7–3 describes possible problems during the boot sequence, specifies their probable cause, and suggests corrective actions. Table 7–3 Boot Sequence Troubleshooting Table Symptom Probable Cause Boot failure Incorrect boot device was specified. Redefine the default boot device at the SRM console as described in Section 4.7 of this guide. Note: Booting "Windows NT" through the KZPSA adapter is not supported. KZPSA is not terminated properly.
Release Notes KZPSA SCSI Storage Adapter Module Be sure to read these notes before installing the KZPSA SCSI Storage Adapter module into your AXP workstation or server. Introduction The KZPSA SCSI Storage Adapter is a high-performance Peripheral Component Interconnect (PCI) option module that serves as a pathway between the system’s PCI I/O bus and a single 16-bit Fast Wide Differential SCSI bus.
StorageWorks KZPSA SCSI Storage Adapter Verified Device Listing Device Type Note FW REV OSF/1 8-bit Single-Ended Devices Windows NT RZ25 RZ25L RZ26 (DSP3105S) 0900 0008 X384 Pass Pass Pass Pass Pass Pass RZ26L RZ28 440C 441C Pass Pass Pass Pass RZ28B RZ73 RZ74 0006 T366 427H Pass Pass Pass Pass Pass Pass 430B 9003 Pass Pass Pass Pass 0491 04AT 045H 02B5 00X2 4.
Release Notes Mandatory Console Code Update During the qualification testing of the KZPSA, some critical problems were found with the console code for the AlphaServer systems. You need to update your systems with the new code provided on the diskettes included with this option. If you have an AlphaServer 1000, locate diskette AK-QK57A-CA from the option package. The procedure to be followed is from the AlphaServer 1000 Owner’s Guide, Order Number: EK-DTLSV-OG.
StorageWorks KZPSA SCSI Storage Adapter 2. Answer "yes" to the question to confirm update inquiry. Confirm update on: sbarcflash sbsrmflash [Y/N] Y CAUTION The update will take several minutes . Do not terminate the update. Allow it to complete. Failure to do so may result in an inoperable system. 3. When the update is complete, exit the LFU. UPD>exit 4. Answer No to the question “Do you want to do a manual update[y/(n)]”. Do you want to do a manual update[y/(n)] n 5.
A Additional Information This appendix provides the part number of some of the additional items you may need when you install the KZPSA Adapter.
B Sample KZPSA Adapter Configurations This appendix describes three possible configurations in which differential and single-ended SCSI devices, housed within a storage enclosure and external to the host system, are interconnected by way of the KZPSA adapter's external SCSI port connector. B.1 Configuration Summary Table B–1 presents a summary of three configurations of how to connect the adapter to a storage enclosure and external host.
KZPSA PCI-to-SCSI Storage Adapter B.2 Bus Converter Configuration (8-Bit Single-Ended) Figure B–1 shows a KZPSA adapter configured to indirectly communicate with six single-ended 8-bit SCSI devices. The DWZZA (bus converter) resides within the first (SCSI ID 0) slot of the BA350-SA storage shelf. The KZPSA directly interconnects, by way of a point-to-point cable, to the DWZZA-VA.
Appendix B. Sample KZPSA Configurations Figure B–1 Bus Converter Configuration HOST SYSTEM SYSTEM MODULE PCI Bus KZPSA ADAPTER ID 7 DWZZA Bus Converter SCSI ID 6 SCSI ID 5 SCSI ID 4 SCSI ID 3 SCSI ID 2 SCSI ID 1 BN21K-xx Cable BA350-SA STORAGE SHELF xx = length in meters B.3 NUO_010_000581_03D RAID Subsystem Configuration Figure B–2 shows a host system configured to communicate with a Digital HSZ40 RAID Subsystem containing a large array of single-ended 3½-inch halfheight SCSI devices.
KZPSA PCI-to-SCSI Storage Adapter NOTE Refer to your StorageWorks Array Controllers documents for specific information on how to configure an HSZ40/Digital BA350-MA storage shelf and the installation and replacement of its components. B.3.1 Single-Ended SCSI Bus Configuration The BA350 storage shelves are setup in a split-bus configuration by installing the BA350 internal jumper board behind slot 1 and the terminator board behind slot 5. Each bus shares the same terminator.
Appendix B. Sample KZPSA Configurations Figure B–2 RAID Subsystem Configuration HOST SYSTEM SYSTEM MODULE PCI Bus KZPSA ADAPTER Tri-Link Connector H885-AA BN21K-xx Cable BA350-MA SHELF 1 2 3 4 5 6 I N SCSI ID 5 BA350-SA STORAGE SHELVES SCSI ID 4 SCSI ID 3 SCSI ID 2 SCSI ID 1 SCSI ID 0 I N I N SCSI ID 5 SCSI ID 4 SCSI ID 3 SCSI ID 2 SCSI ID 1 SCSI ID 0 I N I N SCSI ID 5 xx = length in meters EK–KZPSA–UG.
KZPSA PCI-to-SCSI Storage Adapter B.4 DECsafe Available Server Environment (ASE) Configuration A DECsafe Available Server Environment provides multi-host access to SCSI devices and a generic failover mechanism for network-based applications and system services using a shared SCSI bus. Figure B–3 shows two KZPSA adapters configured in a DECsafe Available Server environment to communicate with six single-ended 8-bit SCSI devices.
Appendix B.
KZPSA PCI-to-SCSI Storage Adapter B.4.2 SCSI ID Selection One KZPSA adapter is assigned SCSI ID 7 and the other KZPSA adapter is assigned SCSI ID 0. For the SCSI devices, the device address is selected by its physical location within the storage shelf, with the slot number equating to the SCSI ID number. B.4.3 SCSI Bus Termination The differential bus is terminated at each end by the terminators installed on one end of both "Y" cables.
Glossary adapter A device that converts the protocol and hardware interface of one bus type into that of another without changing the functionality of the bus. ANSI Abbreviation for American National Standards Institute, an organization that develops and publishes standards for the computer industry. array controller A hardware/software device that facilitates communications between a host and one or more devices organized in an array.
KZPSA PCI-to-SCSI Storage Adapter differential SCSI bus A signal path where the signal's level is determined by the potential difference between two wires. device General name for any hardware unit connected to the system that is capable of receiving, storing, or transmitting data. device driver An operating system software module used to physically control an I/O device.
Glossary port Socket on the front or back of the system unit to which a terminal, printer, modem or other device is connected. RAID Redundant Array of Independent Disks. A methodology in which disks are viewed as a single virtual disk. script Collection of console commands that run in a set order. SCSI Interface designed for connecting disks and other peripheral devices to a computer system. SCSI, pronounced skuh-zee, is used by many computer and peripheral vendors throughout the computer industry.
KZPSA PCI-to-SCSI Storage Adapter SCSI jumpers Removable electrical connectors on some drives that determine the SCSI address setting of the drive. Each installed drive must have a unique address setting for proper communication between the system and all drives. See also SCSI device ID. SCSI port Hardware: the name of the logical socket at the rear of the system unit to which a SCSI device is attached. Software: the channel that controls communications to and from a specific SCSI bus in the system.
Glossary terminator Resistor array device used for terminating a SCSI bus. A SCSI bus must be terminated at its two physical ends. A peripheral device uses a terminator only if it is at the end of the bus. wrist strap See antistatic wrist strap. EK–KZPSA–UG.
Reader’s Comments Manual Order Number: EK–KZPSA–UG. B01 Digital is committed to providing the best products and services. Since our manuals are important components of our products, we value your comments, corrections, and suggestions for improvements. Please take a few minutes to fill out and return this form. Attach additional sheets, if necessary. Thank you.