User Manual
Table Of Contents
- X16 SATA Product Manual
- Seagate® Technology Support Services
- 1.0 Introduction
- 2.0 Drive specifications
- 2.1 Specification summary tables
- 2.2 Formatted capacity
- 2.3 Recording and interface technology
- 2.4 Start/stop times
- 2.5 Power specifications
- 2.6 Environmental limits
- 2.7 Acoustics
- 2.8 Test for Prominent Discrete Tones (PDTs)
- 2.9 Electromagnetic immunity
- 2.10 Reliability
- 2.11 Agency and Safety Certifications
- 2.12 Environmental protection
- 2.13 Corrosive environment
- 2.14 Reference documents
- 2.15 Product warranty
- 3.0 Configuring and mounting the drive
- 4.0 About self-encrypting drives
- 4.1 Data encryption
- 4.2 Controlled access
- 4.3 Random number generator (RNG)
- 4.4 Drive locking
- 4.5 Data bands
- 4.6 Cryptographic erase
- 4.7 Authenticated firmware download
- 4.8 Power requirements
- 4.9 Supported commands
- 4.10 RevertSP
- 4.11 ATA Security Erase Unit Command on SED SATA drives
- 4.12 Sanitize Device - CRYPTO SCRAMBLE EXT
- 5.0 Serial ATA (SATA) interface
Seagate Exos X16 SATA Product Manual, Rev. F 37
www.seagate.com Serial ATA (SATA) interface
59 (Bit 15: 0) Block Erase Ext Not Supported - N
(Bit 14: 1) Overwrite Ext Supported - Y
(Bit 13: X) Crypto Scramble Ext Supported (SED Only) - N
(Bit 12: 1) Sanitize feature set supported - Y
(Bit 11: 1) Commands allowed during sanitize op as specified in ACS-3 - Y
(Bit 10: 1) Sanitize Antifreeze Lock Ext command supported - Y
5D10
H
(512E) / 5D02
H
(4KN)
60–61 Total number of user-addressable LBA sectors available
(see Section 2.2 for related information)
*Note: The maximum value allowed in this field is: 0FFFFFFFh (268,435,455 sectors,
137GB). Drives with capacities over 137GB will have 0FFFFFFFh in this field and the
actual number of user-addressable LBAs specified in words 100-103. This is required for
drives that support the 48-bit addressing feature.
0FFFFFFFh*
62 Obsolete 0000
H
63 Multiword DMA active and modes supported (see note following this table) xx07
H
64 Advanced PIO modes supported (modes 3 and 4 supported) 0003
H
65 Minimum multiword DMA transfer cycle time per word (120 ns) 0078
H
66 Recommended multiword DMA transfer cycle time per word (120 ns) 0078
H
67 Minimum PIO cycle time without IORDY flow control (240 ns) 0078
H
68 Minimum PIO cycle time with IORDY flow control (120 ns) 0078
H
69 Additional supported 0008
H
70–74 ATA-reserved 0000
H
75 Queue depth 001F
H
76 Serial ATA capabilities 8D0E
H
77 (Bit 6:1) Send/Receive FPDMA Queued Commands Supported xx4x
H
78 Serial ATA features supported 00CC
H
79 Serial ATA features enabled xxxx
H
80 Major version number 0FE0
H
(ACS-4)
81 Minor version number FFFF
H
82 Command sets supported 306B
H
83 Command sets supported 7561
H
84 Command sets support extension (see note following this table) 6163
H
85 Command sets enabled 3069
H
86 Command sets enabled B441
H
87 Command sets enable extension 6163
H
88 Ultra DMA support and current mode (see note following this table) xx7F
H
89 Security erase time xxxx
H
90 Enhanced security erase time xxxx
H
92 Master password revision code FFFE
H
Table 15 Identify Device command
Word Description Value