Installation guide

CABDCD
Cabinet DC Distribution Unit
Fault
A DC distribution unit faulted.
CABFAN Broken Cabinet Fan A cabinet fan failed.
CABFLT
Cabinet Fault Detected
A component in the cabinet faulted.
CABFLT
Cabinet Fault Light On
The cabinet fault light is on.
CABLE
PCI Power Cable Missing This PCI backpanel cable is not attached.
CABPCU
Cabinet Power Control Unit Fault
A power control unit faulted.
CABPSU
Cabinet Power Supply Unit Fault
A power supply unit faulted.
CABPWR
Broken Cabinet Power Controller
A cabinet power controller failed.
CABTMP
Cabinet Battery Temperature
Fault
A cabinet battery temperature above the safety
threshold was detected.
CABTMP
Cabinet Temperature Fault
A cabinet temperature above the safety threshold was
detected.
CDCREG
Cabinet Data Registers Invalid
The cabinet data collector is returning incorrect
register
information. Upgrade the unit.
CHARGE Charging Battery
A battery CRU/FRU is charging. To leave this state,
the battery needs to
be permanently bad or fully
charged.
DSKFAN
Disk Fan Faulted/Missing The disk fan either faulted or is missing.
ENC OK
SCSI Peripheral Enclosure OK
The SCSI peripheral enclosure is OK.
ENCFLT
SCSI Peripheral Enclosure Fault A device in the tape/disk enclosure faulted.
FIBER
Cabinet Fiber-Optic Bus Fault
The cabinet fiber-optic bus faulted.
FIBER
Cabinet Fiber-Optic Bus OK
The cabinet fiber-optic bus is OK.
HARD Hard Error
The driver reported a hard error. A hard error occurs
when a hardware
fault occurs that the system is unable
to correct. Look at the syslog for
related error
messages.
HWFLT Hardware Fault
The hardware device reported a fault. Look at the
syslog for related
error messages.
ILLBRK
Cabinet Illegal Breaker Status
The cabinet data collector reported an invalid breaker
status.
INVREG
Invalid ACU Register
Information
A read of the ACU registers resulted in invalid data.
IPS OK
IOA Chassis Power Supply OK The IOA chassis power supply is OK.
IPSFlt
IOA Chassis Power Supply Fault An I/O Adapter power supply fault was detected.
IS In Service The CRU/FRU is in service.
LITEOK
Cabinet Fault Light OK
The cabinet fault light is OK.
MISSNG
Missing replaceable unit
The ACU on the DNCP Series 400-CO (PA-8500) is
missing, electrically
undetectable, removed, or deleted.
MTBF
Below MTBF Threshold
The CRU/FRU’s rate of transient and hard failures
became too great.
NOPWR No Power The CRU/FRU lost power.
OVERRD
Cabinet Fan Speed Override
Active
The fan override (setting fans to full power from the
normal 70%) was
activated.
PC Hi
Power Controller Over Voltage
An over-voltage condition was detected by the power
controller.
PCIOPN
PCI Card Bay Door Open
The PCI card-bay door is open.
Appendix - Fault Isolation