User manual
SANtools® S.M.A.R.T. Disk Monitor (SMARTMon-UX)204
SANTOOLS® is registered in US Patent and Trademark Office No 3,107,854 All rights reserved.
Disk at Channel:ID 00:02 [Optimal]
Disk at Channel:ID 00:03 [Optimal]
Disk at Channel:ID 00:04 [Optimal]
Disk at Channel:ID 00:05 [Optimal]
Disk at Channel:ID 00:06 [Reserved-Status]
Disk at Channel:ID 00:07 [Optimal]
Disk at Channel:ID 00:08 [Optimal]
Disk at Channel:ID 00:09 [Optimal]
Disk at Channel:ID 00:10 [Optimal]
Disk at Channel:ID 00:11 [Optimal]
Disk at Channel:ID 00:12 [Failed-WriteFailure]
Disk at Channel:ID 00:13 [Optimal]
Disk at Channel:ID 00:14 [Optimal]
Disk at Channel:ID 00:15 [Optimal]
Disk at Channel:ID 01:00 [Optimal]
Disk at Channel:ID 01:01 [Optimal]
Disk at Channel:ID 01:02 [Optimal]
Disk at Channel:ID 01:03 [Optimal]
Disk at Channel:ID 01:04 [Optimal]
Disk at Channel:ID 01:05 [Optimal]
Disk at Channel:ID 01:06 [Optimal]
Disk at Channel:ID 01:07 [Optimal]
Disk at Channel:ID 01:08 [Optimal]
Disk at Channel:ID 01:09 [Optimal]
Disk at Channel:ID 01:10 [Optimal]
Disk at Channel:ID 01:11 [Optimal]
Disk at Channel:ID 01:12 [Optimal]
Disk at Channel:ID 01:13 [Optimal]
Disk at Channel:ID 01:14 [Optimal]
Disk at Channel:ID 01:15 [Optimal]
Disk at Channel:ID 02:00 [Optimal]
Disk at Channel:ID 02:01 [Optimal]
Disk at Channel:ID 02:02 [Optimal]
Disk at Channel:ID 02:03 [Optimal]
Disk at Channel:ID 02:04 [Optimal]
Disk at Channel:ID 02:05 [Optimal]
Disk at Channel:ID 02:06 [Optimal]
Disk at Channel:ID 02:07 [Optimal]
Disk at Channel:ID 02:08 [Optimal]
Disk at Channel:ID 02:09 [Optimal]
Disk at Channel:ID 02:10 [Optimal]
If the selected device is a LUN that is presented by a RAID subsystem with an Infortrend controller in it, you will get
the output that is highlighted in Blue. If it is not an Infortrend controller, the software will report the EVPD data
described in the Inquiry Page Viewer section.
Additional Information
· Unless you (or your RAID provider) has configured the engine otherwise, you can query this RAID engine by
sending the -I+ and -z command to any LUN.
· Significantly more information will be made available in future releases.
· RAID subsystem manufacturers and VARs/OEMs mask the make & model of RAID engine they are using by
changing the make and model fields. You may have a LSI-based subsystem and not know it.
· By design, our software does NOT allow you to change any configurable parameters except for mode pages. You
cannot use our software as a "configurator".
· If you send the -z command to a device which is not a logical disk associated with a Mylex (or Infortrend) RAID
engine, the device will reject the command and our software will just reject the command.
· We support reporting all LSI defined physical device states. The values that may be returned are shown in the LSI
Drive Status Definitions table below. The state is shown between braces, so a drive in Optimal state will be
reported as [Optimal] and Out of Service will be reported as [Out-of-Service].
LSI Drive Status Definitions
Status String
Meaning
Optimal
The drive is in good condition and is currently configured
as part of a LUN or global hot spare.
Unassigned
The controller has detected a drive present, but the drive
53
204 204
205