User manual
SANtools® S.M.A.R.T. Disk Monitor (SMARTMon-UX)46
SANTOOLS® is registered in US Patent and Trademark Office No 3,107,854 All rights reserved.
Array Device (2) "Dk2"
Array Device (3) "Dk3"
Array Device (4) "Dk4"
Array Device (5) "Dk5"
Array Device (6) "Dk6"
Array Device (7) "Dk7"
Array Device (8) "Dk8"
Array Device (9) "Dk9"
Array Device (10) "Dk10"
Array Device (11) "Dk11"
Power Supply (0) "PSUL"
Power Supply (1) "PSUU"
Cooling Element (0) "Fn0"
Cooling Element (1) "Fn1"
Cooling Element (2) "Fn2"
Cooling Element (3) "Fn3"
Cooling Element (4) "Fn4"
Cooling Element (5) "Fn5"
Cooling Element (6) "Fn6"
Cooling Element (7) "Fn7"
Cooling Element (8) "Fn8"
Cooling Element (9) "Fn9"
Temperature Sensor (0) "Int"
Temperature Sensor (1) "Ext"
Temperature Sensor (2) "CPU0"
Temperature Sensor (3) "CPU1"
Temperature Sensor (4) "Mobo"
Temperature Sensor (5) "DIMM"
SESElectronics Processor (0) "EMC/CPLD Ver-0x3-0x1"
SESElectronics Processor (1) "01A"
SESElectronics Processor (2) "Intel Starlake S5000PSL"
SESElectronics Processor (3) "Woodcrest Xeon"
SESElectronics Processor (4) "Woodcrest Xeon"
SESElectronics Processor (5) "IntelSRCSAS144E"
SESElectronics Processor (6) "DIMM"
Display Unit (0) "Flt"
Display Unit (1) "ID"
SAS Expander (0) "Exp"
T10 Compliance (0) "T10"
Threshold Information Warning Range Critical Range
Temperature Sensor #0: 16 - 42 16 - 44
Temperature Sensor #1: 8 - 33 8 - 35
Temperature Sensor #2: 158 - 253 142 - 254
Temperature Sensor #3: 158 - 253 142 - 254
Temperature Sensor #4: 16 - 63 16 - 65
Temperature Sensor #5: 158 - 253 142 - 254
Module Locations - Front View
Col-1 Col-2 Col-3 Col-4
+--------------------------------------+
|SLOT 00 | SLOT 01 | SLOT 02 | SLOT 03 | Row-1
|SLOT 04 | SLOT 05 | SLOT 06 | SLOT 07 | Row-2
|SLOT 08 | SLOT 09 | SLOT 10 | SLOT 11 | Row-3
+--------------------------------------+
Module Locations - Rear View
+--------------------------------------+
| PSU1/ Cooling | Rest of system IO |
| PSU0/ Cooling | ports from Mobo |
+--------------------------------------+
Internal Device Information
Bay Type SAS Expander Address SAS Device Address
------------------------------------------------------------
1 SATA 50-05-0C-C1-01-AB-C7-00 50-05-0C-C1-01-AB-C7-01
2 SATA 50-05-0C-C1-01-AB-C7-00 50-05-0C-C1-01-AB-C7-02
3 SATA 50-05-0C-C1-01-AB-C7-00 50-05-0C-C1-01-AB-C7-03
4 SATA 50-05-0C-C1-01-AB-C7-00 50-05-0C-C1-01-AB-C7-04
5 SATA 50-05-0C-C1-01-AB-C7-00 50-05-0C-C1-01-AB-C7-05
6 SATA 50-05-0C-C1-01-AB-C7-00 50-05-0C-C1-01-AB-C7-06