Owner`s manual
Section 1. Introduction
10
q The Main Power Switch switches electrical power to the machine ON and OFF.
The cabinet door cannot be opened until the power switch is turned off.
q The Main Power Circuit Breakers provide over-current protection.
q The Power Cable Entrance is the point where the cable connected to the power
source enters the machine. It connects the machine to one of the following power
sources:
• 200-240VAC, 50/60 Hz, single phase, 56 Amps max current.
• 200-240VAC, 50/60 Hz, three phase, 27 Amps per phase
Maximum Power Consumption in either configuration: 13,440 Watts
It is strongly recommended that the machine is fed from an “Earth Leakage”
protected electrical outlet – if in doubt, please contact Seal Graphics Technical
Services (listed at rear of manual) or consult a licensed electrician
q The Compressed Air Connection is located on the lower back of the left side
cabinet where an outside source of compressed air is connected. A 90 – 100psi @
4cfm (6–7 bar @) 113L
3
/minute) compressed air supply is required. The maximum
inlet pressure is 125psi (8.5 bar).
q The Take-up Roller is located on the back of the machine and is used to pull the
material through the machine and wind the finished material up.
q The Cooling Fan Assembly (located beneath the Take-up Roller) contains fans to
cool the media down before it rolls up. The Cooling Fan Assembly automatically
switches on when the machine is put into Run mode.
Figure 1-3 shows the rear view of the liquid laminator. Major components (safety items
shown in red) include the following:
Figure 1-3. Rear View
Main Power
Switch
Circuit Breakers
Power Cable
Entrance
Cooling
Fans
Take
-
up
Roller