Owner`s manual

Section 1. Introduction
10
q The Main Power Switch switches electrical power to the machine ON and OFF.
The cabinet door cannot be opened until the power switch is turned off.
q The Main Power Circuit Breakers provide over-current protection.
q The Power Cable Entrance is the point where the cable connected to the power
source enters the machine. It connects the machine to one of the following power
sources:
200-240VAC, 50/60 Hz, single phase, 56 Amps max current.
200-240VAC, 50/60 Hz, three phase, 27 Amps per phase
Maximum Power Consumption in either configuration: 13,440 Watts
It is strongly recommended that the machine is fed from an “Earth Leakage”
protected electrical outlet if in doubt, please contact Seal Graphics Technical
Services (listed at rear of manual) or consult a licensed electrician
q The Compressed Air Connection is located on the lower back of the left side
cabinet where an outside source of compressed air is connected. A 90 100psi @
4cfm (67 bar @) 113L
3
/minute) compressed air supply is required. The maximum
inlet pressure is 125psi (8.5 bar).
q The Take-up Roller is located on the back of the machine and is used to pull the
material through the machine and wind the finished material up.
q The Cooling Fan Assembly (located beneath the Take-up Roller) contains fans to
cool the media down before it rolls up. The Cooling Fan Assembly automatically
switches on when the machine is put into Run mode.
Figure 1-3 shows the rear view of the liquid laminator. Major components (safety items
shown in red) include the following:
Figure 1-3. Rear View
Main Power
Switch
Circuit Breakers
Power Cable
Entrance
Cooling
Fans
Take
-
up
Roller