Use & Care Guide Manual de Uso y Cuidado System tested and certified by NSF International against NSF/ANSI Standard 44 for hardness reduction and efficiency. ® English / Español Este sistema ha sido probado y certificado por NSF International de acuerdo a Norma NSF/ANSI 44 para la reducción de la dureza y eficiencia. Kenmore Water Softener Model / Modelo No. 625.
Warranty WARRANTY ON KENMORE WATER SOFTENER ONE YEAR LIMITED WARRANTY ON WATER SOFTENER When installed, operated and maintained according to all instructions supplied with the product, if this Kenmore appliance fails due to a defect in material and workmanship within one year from the date of purchase, call 1-800-4-MY-HOME® to arrange for free repair.
Table of Contents Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Safety Guides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Specifications & Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications & Dimensions Model No. 625.383000 Model Code Rated Softening Capacity (Grains @ Salt Dose) Rated Efficiency (Grains/Pound of Salt @ Minimum Salt Dose) Rated Service Flow Rate Amount of High Capacity Ion Exchange Resin Pressure Drop at Rated Service Flow Water Supply Max. Hardness Water Supply Max. Clear Water Iron Water Pressure Limits (minimum / maximum) Water Temperature Limits (minimum / maximum) Minimum Water Supply Flow Rate Maximum Drain Flow Rate 300 8,300 @ 1.7 lbs. 20,400 @ 6.
Packing List The parts required to assemble and install the water softener are included with the unit. Thoroughly check the water softener for possible shipping damage and parts loss. Also inspect and note any damage to the shipping carton. Remove and discard (or recycle) all packing materials. To avoid loss of small parts, we suggest you keep the small parts in the parts bag until you are ready to use them. Small Parts Ground Clamp Kit Bypass Valve Hose Clamps 20 ft.
Plan Your Installation TYPICAL INSTALLATION Hard W Soft, hot water ater Lin Soft W ater Lin e e Soft Water to R.O. System Shutoff Valve 120V, 60 Hz Hard Water to House Water Heater to R.O. Faucet Reverse Osmosis System R.O. Storage Tank ain Soft, cold water) Outside Faucet (hard water) R.O.
Plan Your Installation CHECK YOUR WATER PRESSURE BEFORE INSTALLING For your water softener to work properly, incoming water pressure in your house pipes must be no lower than 20 pounds per square inch (psi). The highest allowable pressure is 125 psi. If pressure is above 125 psi, buy and install a pressure reducing valve in the pipe supplying water to the softener’s inlet. NOTE: If water pressure during the day is 100 psi or more, pressure during the night may go above 125 psi.
Installation INSTALL SINGLE BYPASS VALVE (cont.) ASSEMBLE INLET AND OUTLET PLUMBING Before installing the bypass valve and/or installation adaptors, make sure that the turbine and support are firmly in place inside the softener valve’s outlet port. Measure, cut (thread if needed) and put together all pipe and fittings up to the main water pipe. Make sure that the incoming water supply pipe goes to the valve inlet side. CAUTION: Never solder fittings while connected to nonmetallic parts.
Installation CONNECT THE VALVE DRAIN HOSE Take a length of 3/8” inside diameter drain tubing (supplied) and attach one end to the drain fitting (see Fig. 11). Use a tube clamp from the parts bag to hold it in place. Put the other end of the tubing over a floor drain, into a laundry tub, standpipe, or other suitable drain. Check your local codes. Leave an air gap of about 1-1/ 2'' between the end of the hose and the drain. This gap is needed so you don’t get a backflow of sewer water into the softener.
Installation LEAK TEST To check for leaks, complete the following steps: CAUTION: To avoid water or air pressure damage to softener inner parts, and to flush pipe chips or other residue from the water pipes, be sure to do the following steps exactly as instructed. 1. Fully open two nearby cold water faucets downstream from the softener. 2. Place bypass valve(s) in “bypass” position (see Figures 12 & 13). On a single valve, slide the stem inward to bypass.
Installation INSTALL GROUNDING CLAMP The house cold water pipe (iron or copper) is often used to ground all electrical outlets in the home. To maintain this ground, use the ground clamp kit included in the parts bag. Install the ground clamp across the inlet and outlet metal pipes (see Fig. 14). Make sure good contact is made between the pipe and the clamps. INSTALL COVERS After installing your water softener, put the covers on.
Programming the Softener Display LOW SALT indicator UP button Low Salt press for tonight Select hold for immediate REGENERATION button SELECT button PROGRAM THE SOFTENER When the transformer is plugged into the electrical outlet, the model code (300) and a test number (example: J3.0, are briefly shown in the display. Then the words “SET TIME” appear and 12:00 PM begins to flash.
Programming the Softener SET RECHARGE (REGENERATION) START TIME If you completed the previous step, the words “SET RECHARGE TIME" should show in the display. Otherwise, press the SELECT button several times until they do. Figure 19 1. The softener’s default recharge start time is 2:00 AM. This is normally a time of day when water is not being used in the household. Hard water bypasses the softener if the household draws water during the recharge cycle.
Sanitizing the Softener SANITIZE THE WATER SOFTENER 1. Open salt lid, remove the brinewell cover and pour about 3 oz. (6 tablespoons) of household bleach into the softener brinewell. Replace the brinewell cover. 2. Make sure the bypass valve(s) is in the “service” (open) position. 3. Start a recharge: Press the REGENERATION button and hold for 3 seconds, until “RECHARGE NOW” begins to flash in the display. This recharge draws the sanitizing bleach into and through the water softener.
Controller Features EXTRA RECHARGE Sometimes, a manually initiated recharge (regeneration) may be desired, or needed. Two examples are: = You have used more water than usual (guests visiting) and you may run out of soft water before the next automatic regeneration. = You did not add salt to the softener before it ran out. Add salt to the softener before regenerating. You can start a regeneration immediately, or you can set the controller to regenerate at the next preset recharge time (2:00 AM, or as set).
Controller Features EFFICIENCY MODE When this feature is ON, the water softener will operate at salt efficiencies of 4000 grains of hardness per pound of salt or higher. The softener may recharge more often using smaller salt dosage and less water. This softener is shipped with the efficiency feature set OFF. Installations in the state of California require this setting to be turned ON. To turn this feature ON: 1. Press and hold the SELECT button until the display shows “000 - -”.
Care of Your Water Softener SALT BRIDGE Sometimes, a hard crust or salt “bridge” forms in the brine tank. It is usually caused by high humidity or the wrong kind of salt. When the salt “bridges,” an empty space forms between the water and the salt. Then, salt will not dissolve in the water to make brine. Without brine, the resin bed is not recharged and hard water will result. If the storage tank is full of salt, it is difficult to tell if you have a salt bridge. A bridge may be underneath loose salt.
Service Information TROUBLESHOOTING If your water softener does not work properly, make the following easy checks. Often, you will find what is wrong yourself and you won’t have to call and wait for service. If you do not find anything wrong while making the checks, and your softener still does not work properly, call your Sears Service Department. PROBLEM CAUSE No soft water No salt in the storage tank.
Service Information MANUALLY INITIATED ELECTRONIC DIAGNOSTICS 1. To enter diagnostics, press and hold the SELECT button until “000 - -” shows in the display. Figure 32 TURBINE OPERATION: If no water is flowing through the softener, the turbine indicator displays three zeros. When water is flowing, a 000 to 199 count repeats for each gallon of water passing through the turbine. To check for positive operation of the turbine if zeros are shown, open a nearby soft water faucet and observe the turbine count.
Service Information MANUAL ADVANCE REGENERATION CHECK This check verifies proper operation of the valve motor, brine tank fill, brine draw, regeneration flow rates, and other controller functions. Always make the initial checks first, and perform the manually initiated electronic diagnostics. NOTE: The display must show a steady time (not flashing). If an error code shows, first press the SELECT button to enter the diagnostic display. 1. Press the REGENERATION button and hold in for 3 seconds.
Notes Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.
Water Softener Exploded View 1 Kenmore Model No. 625.383000 3 2 Valve Assembly See Pages 24 & 25 for parts 4 5 24 25 23 6 Rating Decal Location 26 21 20 22 19 18 7 8 9 11 12 13 27 28 17 16 15 14 29 57 10 22 Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.
Softener Parts List Key No. 1 2 3 Part No. 6 7 7275907 7324926 7324934 7325029 7325061 7327819 7324918 7324950 7324895 7219888 ¢ 7327576 8 9 10 á ¢ 7214375 11 12 13 14 15 á ¢ 4 5 ¢ á á á 7324879 1103200 9003500 Description Transformer, 24V, 10VA Top Cover Salt Lid (order decal below) Instruction Decal, English Instruction Decal, Spanish Repl. Electronic Controller (PWA) Faceplate (order decal below) Faceplate Decal Rim Brinewell Cover Brinewell Mounting Hardware Kit (includes Key Nos.
Valve Assembly Exploded View 52 50 51 95 94 96 52 93 53 92 54 55 56 57 91 88 87 60 90 86 85 Wear Strip Seal 62 Cross-Section View 67 68 63 83 82 69 64 81 65 77 80 58 61 89 84 59 79 78 66 72 73 75 74 71 70 76 24 Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.
Valve Parts List Key No. 50 51 52 53 54 55 56 57 58 59 60 ¢ Part No. Description 7224087 7286039 0900857 7231385 0503288 7284964 7142942 0900431 7024160 7170327 0501226 7129716 Screw, #8-32 x 1” (2 req.) Motor (incl. 2 ea. of Key No. 50) Screw, #6-20 x 3/8” (2 req.) Motor Plate Bearing Cam & Gear Clip, Drain Tubing Clamp (2 provided) Adaptor, Drain Hose O-Ring, 5/8” x 13/16” Flow Plug, 0.9 gpm Seal Kit, (includes Key Nos.
Get it fixed, at your home or ours! Your Home For expert troubleshooting and home solutions advice: www.managemylife.com For repair – in your home – of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner’s manuals that you need to do-it-yourself. For Sears professional installation of home appliances and items like garage door openers and water heaters.