M. C-MOTOR, THERMISTOR AND
SHEATH HEATER REMOVAL
1) Remove the back cover by removing the four screws
securing the cover assembly to the oven cavity.
2) Disconnect the leadwire from the circulation motor
and the sheath heater terminal.
3) Remove four hex nuts holding chamber assembly
to the oven cavity.
4) Remove the screws of the thermistor, and lift up
chamber assembly.
5) Remove a hex nut securing the circulation fan to
shaft of the C-motor.
6) Remove screws securing sheath heater to
chamber wall.
7) Remove sheath heater from chamber assembly.
N. SENSOR REMOVAL
1) Disconnect the sensor connector from P.C.B. Sub
assembly.
2) Remove the screw securing sensor to Air tunnel.
5-7
L. INTERLOCK SYSTEM
1) INTERLOCK MECHANISM
The door lock mechanism is a device which has
been specially designed to stop microwave activity
when the door is opened during cooking and thus
to prevent the danger resulting from the microwave
leakage.
2) MOUNTING OF THE PRIMARY/MONITOR/
SECONDARY SWITCHES TO THE LATCH
BOARD
3) INSTALLATION AND ADJUSTMENT OF THE
LATCH BOARD TO THE OVEN ASSEMBLY
• Mount the latch board to the oven assembly.
• Adjust the latch board in the arrow direction so that
oven door will not have any play in it when the door
is closed.
• Tighten the mounting screw.
Check for play in the door by pulling and
pushing the door handle. Door movement
should be less than 1/64 inches. (0.5 mm)
Don't pull the door handle while making this
adjustment. Make sure that the latch moves
smoothly after adjustment is completed and that
the screws are tight. Make sure the primary,
monitor, and secondary switches operate properly
by following the continuity test procedure.
PRIMARY
SWITCH
SECONDARY
SWITCH
ADJUSTMENT
DIRECTION
MONITOR
SWITCH