SDS

Safety Data Sheet Version: V1.3
According to 2012 OSHA Hazard Communication Standard
(29 CFR 1910.1200)
REPORT NO.: LCS180824073ASD
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Page 9 of 12
Chemical
name
Toxicity to Algae
Toxicity to Fish
Toxicity to
Microorganisms
Daphnia Magna
(Water Flea)
Copper
7440-50-8
96h EC50: 0.031 -
0.054
mg/L
(Pseudokirchneriella
subcapitata) 72h
EC50:
0.0426 - 0.0535
mg/L
(Pseudokirchneriella
subcapitata)
96h LC50: 0.0068 -
0.0156
mg/L (Pimephales
promelas)
96h LC50: = 0.112 mg/L
(Poecilia reticulata) 96h
LC50: = 0.3 mg/L
(Cyprinus
carpio) 96h LC50: = 0.8
mg/L (Cyprinus carpio)
96h
LC50: = 1.25 mg/L
(Lepomis
macrochirus) 96h LC50: =
0.052 mg/L
(Oncorhynchus
mykiss) 96h LC50: = 0.2
mg/L (Pimephales
promelas)
96h LC50: < 0.3 mg/L
(Pimephales promelas)
48h EC50: = 0.03 mg/L
Carbon black
1333-86-4
24h EC50: > 5600 mg/L
Persistence and Degradability
No information available.
Bioaccumulation
No information available.
Other adverse effects
No information available.
Section 13- Disposal Considerations
Waste treatment methods
Disposal methods
This material, as supplied, is not a hazardous waste according to Federal
regulations (40 CFR 261). This material could become a hazardous waste if
it is mixed with or otherwise comes in contact with a hazardous waste, if
chemical additions are made to this material, or if the material is processed
or otherwise altered. Consult 40 CFR 261 to determine whether the altered
material is a hazardous waste. Consult the appropriate state, regional, or
local regulations for additional requirements.
Contaminated Packaging
Disposal should be in accordance with applicable regional, national and
local laws and regulations.
California Hazardous Waste Codes 141
This product contains one or more substances that are listed with the State of California as a hazardous waste.
Chemical Name
California Hazardous Waste
Lithium Cobalt Oxide (CoLiO
2
)
12190-79-3
Toxic
Copper
7440-50-8
Toxic
Aluminum foil
7429-90-5
Ignitable powder