SEBO AUTOMATIC X-Series MADE IN GERMANY Please Retain for Reference
SEBO AUTOMATIC Owner‘s Manual Table of Contents Technical Details .................................................................................................................. Important Safety Instructions ............................................................................................... Special SEBO Product Features ........................................................................................... Automatic Power Head Height Adjustment .....................................
! IMPORTANT SAFETY INSTRUCTIONS Please read all instructions before using this machine ELECTRICAL APPLIANCE CAUTION! Failure to follow the safety instructions marked with this symbol can pose a hazard. • Do not use with a damaged cable. • Disconnect from mains when not in use and before handling the machine for any pur- • • • • • • • • pose other than vacuuming. Always turn off and unplug the machine before undertaking any maintenance.
TO ENSURE GUARANTEE COVER • • • • • • • • Do not re-use bags. Do not wash filters. Do not vacuum sharp objects, hot material, eg. fire ash or hazardous/harmful dust. Do not leave near heat source, eg. fires, ovens, radiators, etc. Do not remove any screws. All repairs must be authorised by SEBO. Do not use on inappropriate surfaces, eg. concrete, stone, gravel. Do not expose to liquid or moisture. Change bags and filters at correct intervals. Only use genuine SEBO bags, filters and spares.
SPECIAL SEBO PRODUCT FEATURES Your SEBO AUTOMATIC X series vacuum cleaner is the most technically advanced upright vacuum cleaner in the world. Along with its excellent filtration system (99.9% to 0.3 microns], one of its most important features is its ability to „monitor“ the resistance of the brush roller against the floor, so that the proper cleaning height is consistently maintained.
Identification of Parts 1. Handle grip 2. On/Off switch 3. Handle assembly 4. Retaining ring 5. Cover release flap 6. Dust bag housing 7. Front cover 8. Housing release button 9. Power head with brush 10. Cable (cord) 11. Attachment tube handle 41 42 46 43 47* 48* 45 44* Standard Attachments 18 17 17. Crevice nozzle 18. Upholstery nozzle Optional Attachments 41. Wall and floor brush - Part No 1325 GY 42. Turbo brush for stairs - Part No 6179 ER 43. Radiator brush - Part No 1496 ER 44.
Operating Instructions Starting The Machine A. Before turning on your vacuum cleaner, make sure that the vacuum handle is in its upright locked position and that you have a firm hold on the handle grip to keep the machine from moving forward. 15 1. Turn the quick release cable hook (15) to the up position by moving it to the left or right and release the cable. 2. Release the cable from the upper cable hook (26). 3. Plug in and press the switch (2) to the „I“ position.
Using the Attachments Tube, Hose & Attachments - Figures 1 & 2 The attachment tube (16) is useful for vacuuming corners and hard-to-reach areas. The handle grip (1) should be in the upright, locked position (as shown in figure 1). Grip the attachment tube handle (11), pull it up and away from the machine and stretch out the hose (12) until it locks (this locking action will prevent the hose from retracting back into the attachment tube while it is in use).
Maintenance ! Dust Bag Part No 5093 ER Figure 7 Micro Filter Part No 5036 ER Figure 8 Always unplug vacuum from socket before handling! Changing the Dust Bag - Figure 7 To change the dust bag, pull the cover release flap forward (#5 on page 5) and lift the cover (7) from the dust bag housing. The cover release flap must remain in a forward „pulled-out“ position to change dust bags and lock them into place.
Clog Removal ! Always unplug vacuum from socket before handling! Clogs in the Base - Figure 12 Figure 12 Most clogs can be removed by accessing the airflow pathway via the orange access door [38) located on the underside of the power head. However, other clogs may only be removed by accessing the airflow pathway by disassembling the machine in the opposite sequence of the machine‘s original assembly (see assembly, page 5).
Trouble-Shooting Guide ! Always unplug vacuum from socket before handling ! PROBLEM Does not turn on or machine shut off intermittently REASON SOLUTION 1. Handle not fully inserted into the bag housing, causing a faulty connection. 1. Release handle catch, push handle down, close handle catch. 2.Not plugged into good socket. 2. Use another socket. 3. Cable worn/ damaged. 3. Replace cable. 4. Dust bag housing (6) not fitted to power head correctly. 4. Re-fit dust bag housing.
Carpet cleaning with the SEBO AUTOMATIC upright vacuum cleaners and SEBO DUO-P Carpet cleaning powder Step 1 Disconnect the hose by squeezing the retaining ring (No. 4 in the instruction manual) and pulling the hose end out of the connecting tube (No. 23 in the manual). Then simply leave the hose end free. Step 2 Spot clean any prominent stains with DUO-P cleaning powder and the brush from the SEBO Clean Box. Step 3 Sprinkle DUO-P cleaning powder evenly over the area to be cleaned.