User Manual

ENFORCER Curtain Sensors
2 SECO-LARM U.S.A., Inc.
1
7
/
32
” (30.6mm)
1
5
/
16
” (33.5mm)
Features ....................................................... 2
Parts List ....................................................... 2
Dimensions ................................................... 2
Specifications ............................................... 2
Sample Installations ..................................... 3
Choosing a Location ................................. 3~4
Selectable 3-Channel Beam Frequency ....... 4
Mounting the Curtain Sensor .................... 4~5
1x Transmitter
1x Receiver
4x L-Brackets
1x Manual
Mounting hardware
Running the Wires ........................................ 5
Connecting the Wires ................................ 5~6
Removing the Lens Caps .............................. 6
Connecting One or More Sensors ................ 7
Mounting the Transmitter and Receiver and
Testing the Sensor .................................... 7
Tamper Protection ........................................ 8
Troubleshooting ............................................ 8
Specifications:
Dimensions:
11.25” (29cm) E-9611-2x25
22.5” (57cm) E-9622-4x25
44.5” (113cm) E-9644-6x25
60.1” (153cm) E-9660-8B25
79” (201cm) E-9680-10B25
Top View
Side View
Multi-frequency to reduce interference
between multiple units
Install on windows, doorways, skylights,
fence tops, and any place where space is
limited
Perfect for indoor and outdoor perimeter
security
Slimline design 1
5
/
16
x
7
/
8
(33x22 mm)
Rugged aluminum construction
NO/NC Relay output
2, 4, 6, 8, or 10 separate photoelectric beam
sensors; programmable trigger upon
breaking of any single beam or simultaneous
breaking of any two adjacent beams
Anti-tamper circuit for use when power is cut
or end cap is removed
No synchronizing wires required
LED alignment indicator
L-brackets and mounting hardware included
Model
E-9611-2x25
E-9622-4x25
E-9644-6x25
E-9660-8B25
E-9680-10B25
Standby@12~24 VDC
80mA
89mA
94mA
102mA
110mA
Active@12~24 VDC
60mA
73mA
79mA
92mA
100mA
Dimensions
11
1
/
4
”x1
5
/
16
”x
7
/
8
(286x33x22 mm)
22
1
/
2
”x1
5
/
16
”x
7
/
8
(572x33x22 mm)
44
1
/
2
”x1
5
/
16
”x
7
/
8
(1130x33x22 mm)
60
1
/
8
”x1
5
/
16
”x
7
/
8
(1527x33x22 mm)
79”x1
5
/
16
”x
7
/
8
(2007x33x22 mm)
Response time
0.5~20 ms
0.5~32.5 ms
0.5~48.5 ms
0.5~60 ms
0.5~70 ms
Maximum range
Indoor: 50’ (16m), outdoor: 25’ (8m)
Detection method
Simultaneous break of 2 adjacent beams or any single beam (programmable)
Output
NO/NC Relay output, 1A@12~24 VDC
Operating temperature
-49°~131° F (-45°~55° C)
Attenuation LED
ON: Powered, aligned properly; Flashing: Beam broken or unaligned; OFF: No power
Enclosure / Case
IP65 / Aluminum alloy
3
/
4
” (19.6mm)
7
/
8
” (22.3mm)