The receiver and the transmitter both have a tamper switch on one end to protect against someone
attempting to open the unit. However, there is no separate tamper output to the alarm control
panel. Instead, the alarm output is triggered if the cover of the end cap with the tamper button is
removed, if the transmitter or receiver is moved out of alignment, or if power is disconnected.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to
change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Trademarks
are the property of SECO-LARM U.S.A., Inc. or their respective owners.
Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or
in part, without the written permission of SECO-LARM.
LIMITED WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while
used in normal service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to
the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty
is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or
alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such
equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole
obligation of SECO
-
LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at
SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential
personal or property damage of any kind to the purchaser or anyone else.
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Website: www.seco-larm.com
PICTN1
Phone: (949) 261-2999 | (800) 662-0800
Email: sales@seco-larm.com
MiE-96xx-xxB25_141008.docx
Tamper Protection:
Troubleshooting:
Transmitter LED will not turn
ON
Test the power and ground wire with a voltage meter to
ensure power is connected and is of the correct voltage.
Change the position of the transmitter jumper “JMP0
(see page 6).
Receiver LED will not turn ON
Test the power and ground wire with a voltage meter to
ensure power is connected and is of the correct voltage.
Receiver LED will not turn ON
unless the sensor is triggered
Change the position of the receiver jumper “JMP1”
(see page 6).
Receiver LED flashes
continuously
Check that the transmitter and receiver are aligned.
Does not trigger when beam is
broken
Remount the curtain sensor away from any shiny surface,
or repaint the surface to cut down on reflection.
Receiver continuously triggers
the alarm
Check that the transmitter and receiver are aligned.
Check that the tamper button and the cover for the
tamper button are mounted correctly.
False alarm
Re-install so that multiple sensors do not interfere with
each other.
Cut back leafy vegetation.
Re-mount away from the edge of a roof.