Data Sheet

Example of installing the SLI 259A with an
ENFORCER
®
Alarm and SS-052B Shock Sensor
ENFORCER
®
ALARM BRAIN
BLUE WIRE
YELLOW WIRE
BLACK WIRE
RED WIRE
SHOCK
SENSOR
SS-052B
BLACK WIRE
YELLOW WIRE
BLUE WIRE
RED WIRE
INTERIOR ZONE
ADJUSTMENT KNOB
EXTERIOR ZONE
ADJUSTMENT KNOB
SLI
®®
®®
®
259A
The SLI 259A detects the movement of mass through a
protected area (i.e. an arm reaching into a car or a door being
opened). The SLI 259A has dual-zone protection. It combines
both perimeter pre-intrusion warning and instant interior
trigger protection. It does this by transmitting and receiving a
high-frequency RF signal. When an object moving towards the
vehicle is detected, the high-frequency RF signal will change.
This change will cause the microwave sensor to send a trigger
signal to the alarm.
Features
SLI
®
259A
Dual-Stage Microwave Sensor
ENFORCER
Sensor
®
SECO-LARM
®
U.S.A., Inc.,
16842 Millikan Avenue, Irvine, CA 92606 Tel: 1-800-662-0800 (Domestic U.S. & Canada)
Tel: 1-949-261-2999 (California & International) Fax: 1-949-261-7326 Email: info@seco-larm.com Website: www.seco-larm.com
The SECO-LARM policy is one of continual development. For that reason, SECO-LARM reserves the right to change prices and specifications without notice. SECO-LARM is not responsible for misprints.
SLI259.pmd
SLI 259A Specifications
No. of zones
Trigger output
Pre-alert output
LED
LED status indication
No. of sensitivity
adjustment pods
Programmable
external protection?
2
Transistor ground
Transistor ground
Tri-color
Power-up, incorrectly connected, sensitivity,
internal and external zone trigger status
2
Triggers the alarm if 4 pre-intrusion alerts
occur within 15 sec.
Ideal for vehicles with cloth or open tops, or open sunroofs.
Dual-stage protection — Chirps siren if exterior zone
violated (someone gets too close to car), triggers alarm if
interior zone is violated (break-in or vandalism attempt).
Plugs directly into any ENFORCER alarm. Easily connects
to non-ENFORCER alarms.
Separate microfine sensitivity adjustment of interior and
exterior zones for excellent zone separation.
Built-in LED indicates interior and exterior zone status.