Submittal Sheet

April 2019 DES.D.401.G3.22 1/2
NF7FX
Standard Compressor
R134a
220V 50/60Hz
General
Code number 105G6743
Approvals
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F -30 to 45 -30 to 45
Voltage range V 198 - 242 198 - 242
Max. condensing temperature continuous (short) °F 140 (158) 140 (158)
Max. winding temperature continuous (short) °F 257 (275) 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
LBP MBP HBP LBP MBP HBP
90°F S S F
1
F
1
100°F F
1
F
1
F
1
F
1
110°F
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 15.8
Cut in Current, HST | LST A 15.8
Resistance, main | start winding (77°F) 5.8 12.6
Design
Displacement cu.in 0.44
Oil quantity (type) .oz. 9.13 (polyolester)
Maximum refrigerant charge oz. 14.0
Free gas volume in compressor .oz. 79.7
Weight without electrical equipment lbs. 23.0
Dimensions
Height inch A 8.00
B 7.76
B1
B2
Suction connector location, I.D. in. | angle C 0.320-0.327 | 15°
material | comment Copper | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 25°
material | comment Copper | Rubber plug
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 35°
material | comment Copper | Rubber plug
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
S = Static cooling normally sufcient
O = Oil cooling
F
1
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F
2
= Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
= not applicable in this area

Summary of content (2 pages)