Submittal Sheet
May 2016 DES.D.408.R2.02 1/2
TL5G
Universal Compressor
R134a
220-240V 50/60Hz
General
Code number 102G4553
Approvals EN 60335-2-34
Compressors on pallet 125
Application
Application LBP/HBP
Frequency Hz 50 60
Evaporating temperature °C -30 to 15 -30 to -10
Voltage range V 187 - 254 198 - 254
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
LBP MBP HBP LBP MBP HBP
32°C S S F
2
S S –
38°C S S F
2
S S –
43°C S S F
2
S S –
Remarks on application: HBP at 198 - 254V 50Hz only.
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 5.7 5.4
Cut in Current, HST | LST A 5.7 9.7
Resistance, main | start winding (25°C) Ω 14.5 14.8
Design
Displacement cm
3
5.08
Oil quantity (type) cm
3
280 (polyolester)
Maximum refrigerant charge g 400
Free gas volume in compressor cm
3
1690
Weight without electrical equipment kg 7.5
Dimensions
Height mm A 173
B 169
B1 –
B2 –
Suction connector location/I.D. mm | angle C 6.5 | 30°
material | comment Copper | Rubber plug
Process connector location/I.D. mm | angle D 6.5 | 31.5°
material | comment Copper | Rubber plug
Discharge connector location/I.D. mm | angle E 5.0 | 28°
material | comment Copper | Rubber plug
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
S =Staticcoolingnormallysufcient
O = Oil cooling
F
1
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F
2
= Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area