2. Conducted emissions
Test method :
ISO 7637-2 2nd edition: 2004
Polarity of pulse
amplitude
Maximum allowed value for
vehicles with 24V systems
Measured Pulse amplitude
True value
Positive + 150
FAST +48.00V
SLOW +47.60V
Negative - 450
FAST -1.40V
SLOW -1.20V
3
.
I
mmunity to electromagnetic radiation
Test method :
ISO 11452-4, Third edition 2005 and Corrigendum 1:2009
Bulk current injection testing method (from 20 to 400MHz)
ISO 11452-2 2nd edition: 2004
Free field testing method (from 400 MHz to 2000MHz)
Measurement result:
Frequency range
(MHz)
Test level
Type of
modulation
Test
distance
Antenna position
Result
20~400 60mA AM, 80% 150mm / Passed*
400~800 30volts/m AM, 80% 1 m Vertical Passed*
800~2000 30volts/m PM, 577µs 1 m Vertical Passed*
Remark:
* no degradation of performance of ‘immunity-related functions’.