Number Certificates

TÜV RHEINLAND GROUP
Test Report No. 87-R10-0252/19-00
Type
:
6
0xxx Series
Manufacturer
:
SecoRüt Kfz Electronic GmbH
TÜV Rheinland Luxemburg GmbH Telefon: 00352 / 522909 Master_SNCH_en_R12 Page 13 of 13
2a, Kalchesbruck Telefax: 00352 / 523105 issued: 2018-04-01
L-1852 Luxemburg 87-R10-0252/19-00
Measurement result:
24V system
Test pulse
Test level
Number of
pulse / test
time
Burst cycle /
pulse
repetition time
Required
minimum
function status
*
Status of
function true
value
Result
1
-450V
5000 pulses 0.5s C C Passed
2a
37V
5000 pulses 0.2s B A Passed
2b
20V
10 pulses 0.5s C C Passed
3a
-150V
1 h 90ms A A Passed
3b
150V
1 h 90ms A A Passed
4
-12V
1 pulse N/A C B Passed
Remark:
* Class A: all functions of a device/system perform as designed during and after exposure to disturbance.
Class B: all functions of a device/system perform as designed during exposure. However, one or more of
them can go beyond specified tolerance. All functions return automatically to within normal limits after
exposure is removed. Memory functions shall remain class A.
Class C: one or more functions of a device/system do not perform as designed during exposure but return
automatically to normal operation after exposure is removed.
Class D: one or more functions of a device/system do not perform as designed during exposure and do
not return to normal operation until exposure is removed and the device/system is reset by simple
“operator/use” action.
Class E: one or more functions of a device/system do not perform as designed during and after exposure
and cannot be returned to proper operation without repairing or replacing the device/system.
4
.
I
mmunity to transient disturbances
Test method :
ISO 7637-2 2nd edition: 2004
E13*10R05/01*15073*00
Société Nationale de Certification et d'Homologation