Specifications
SSG 500-series Installation and Configuration Guide
54  Replacing the Air Filter
Figure 20: Installing a Memory Module
9. Locate the appropriate slot for the second 512 MB SIMM DRAM module. Repeat 
step 8 to install the second memory module in the slot.
10. To replace the top panel on the chassis, set the front edge of the top panel into 
the groove that runs along the top front edge of the chassis. Then lower the top 
panel onto the chassis.
11. Use the phillips screwdriver to tighten the screws you removed earlier, securing 
the top panel to the chassis.
Replacing the Air Filter
The front panel of the device includes a cooling air vent. To prevent foreign particles 
from entering the device, the air vent includes a protective cover and, in some 
cases, a filter. 
If the temperature alarm continues to appear, we recommend inspecting the fan 
filter. To remove a filter cover and replace a filter, use the procedures described in 
this section.
NOTE: Depending on the working environment where the device is located, we 
recommend changing the fan filter every six months. The fan filter SKU number is 
SSG-500-FLTR.