Operating instructions

4
201114-01
Terminal Block
From Fixture From AC Source
WIRING
1. Connectthehousewirestotheterminalblock
accordingto diagram (see Figure 4). Make
sureallscrewsonterminalblockaretightened
securely.
2.
Removethestrainreliefcoverandplacethehouse
wiresacrossthestrainrelief(seeFigure5).
3. Replace the strain relief cover and tighten
securely.Note:Becarefulnottoovertighten
anddamagethewiring.
WARNING: Turn power o at circuit
breaker or fuse. Place tape over circuit
breaker switch and verify power is o at
the xture.
Green/YellowGreen/Yellow
Blue Blue or Black
Brow
nR
ed or Brown
Figure 4
UP
Terminal Block
House Wiring
Screw
Strain Relief
Cover
Figure 5
UP
FINAL ASSEMBLY
1. Doublecheckallwiringconnections.
2. Verify the rubber gasket is properly seated
aroundtheedgeofthecanopyextension(see
Figure6).
3. Alignthecenterholeonthexturecanopy
withthecenterholeonthecanopyextension
andattachusingthemountingboltremoved
instep1ofInstallation(seeFigure6).
IMPORTANT:
•Ifwallmounted,makesurethextureis
mounted with the sensor below the bulb
holders.
•If eave mounted, mount the xture with
sensorfacingawayfromthehousewall(see
Eave Installation Information forimportant
sensororientationinformation).
4. Pushtherubberplug rmly intoplace(see
Figure7).
5. Caulk around top half of canopy extension
withsiliconeweathersealant(seeFigure7).
6. Installbulb.Do not exceed wattage rating on
xture label.
Figure 6
Mounting
Bolt
Rubber Gasket
Fixture Canopy (Lamp
head and sensor not
shown for clarity)