4. Loosen the clamp
screw in the sensor
ball joint and gently
rotatethesensor.
5. Walk through the
coverage area noting
where you are when
thelightsturnon(also,
the LED will ash
several times when
motionisdetected).
In
TESTmode,lightwill
stayonfor5secondsaf-
termotionhasstopped
and then turn off.
Movethesensorhead
up,down,orsideways
tochangethecoverage
area.Keep the sensor
at least 2.5 cm (1") away from the bulbs.
6. AdjusttheRANGEasneeded.RANGEset
toohighmayincreasefalsetriggeringdueto
heatsourcesinthecoveragearea(seeTrouble-
shootingsection).
7. Securethesensorheadbytighteningtheclamp
screw.Do not overtighten the screw.
8. SettheamountofON-TIMEyouwantthe
lighttostayonaftermotionisdetected(1,5,
or10minutes).etimerwillresetaslong
asthereismotionpresent.Oncemotionhas
stopped, the timer will time-out after the
selectedamountoftime.
Clamp
Screw
Ball
Joint
Aim Sensor Down
for Short Coverage
Aim Sensor Higher
for Long Coverage
Figure 11
3. Adjustthelampheadbylooseningthelocknut
orusingascrewdriver.elampheadmustbe
mountedhorizontally(seeFigure11).After
positioninglamphead,tightenthelocknut
andapplythreadsealanttoensurelamphead
doesnotrotate.
The halogen light must be
mounted horizontally (+/- 4°).
RIGHT WRONG
TESTING AND ADJUSTMENTS
1. Turn on the circuit breaker and light
switch.
Note:Sensorhasa1
1
/
2
minutewarmupperiod
beforeitwilldetectmotion.Whenrstturned
onwait1
1
/
2
minutes.
2. Set:
•ON-TIMEswitchtoTEST
•RANGEdialtoMidwayposition
Bottom of Sensor
ON-TIME
10 5 1 TEST
MIN MAX
RANGE
21 m
(70 ft.)
2.4 m
(8 ft.)
Maximum
Maximum Range Coverage Angle*
(Side View) (Top View)
180°
WARNING: Risk of re. Do not aim the
bulbs at a combustible surface within 1
meter (3 feet).
1m