Operating instructions
8
201114-01
SPECIFICATIONS
Range.................................................Upto21m(70ft.)[varieswithsurroundingtemperature]
SensingAngle.....................................Upto180°
ElectricalLoad...................................Upto250WattMaximumHalogen
ReplacementBulb..............................T3250W(orless)halogen230VAC
PowerRequirements...........................230VAC,50Hz
OperatingModes...............................TEST,AUTO,andMANUALMODE
ON-Timer..........................................1,5,10minutes
TestTimer..........................................5Seconds
ManualModeTimer..........................Dusk-to-Dawn
IngressProtection...............................IP43
eChamberlainGroupreservestherighttodiscontinueproductsandtochangespecicationsat
anytimewithoutincurringanyobligationtoincorporatenewfeaturesinproductspreviouslysold.
TROUBLESHOOTING GUIDE
SYMPTOM POSSIBLE CAUSE SOLUTION
Lightwillnotcome
on.
1. Lightswitchisturnedo.
2. Bulbislooseorburnedout.
3. Fuseisblownorcircuitbreakeristurnedo.
4. Daylightturn-oisineect.
5. Incorrectcircuitwiring,ifthisisanewinstallation.
6. Lightcontrolaimedinwrongdirection.
1. Turnlightswitchon.
2. Checkbulbandreplaceifnecessary.
3. Replacefuseorturncircuitbreakeron.
4. Recheckafterdark.
5. Verifywiringiscorrect.
6. Re-aimlightcontroltocoverdesiredarea.
Lightcomesonin
daylight.
1. Light control may be installed in a relatively dark
location.
2. LightcontrolisinTEST.
1. e xture is operating normally under these
conditions.
2. SetON-TIMEswitchto1,5,or10minutes.
Lightcomesonfor
noapparentreason.
1. Lightcontrolmaybesensingsmallanimalsorautomobile
trac.
2. Rangeissettoohigh.
1. Re-aimsensor.Reducerange.
2. Reducerange.
Lightstayson
continuously.
1. Bulbispositionedtoclosetothesensororpointedat
nearbyobjectsthatcauseheattotriggerthesensor.
2. esensormaybepickingupaheatsourcelikeanair
vent, dryer vent, or brightly painted, heat-reective
surface.
3. LightcontrolisinManualmode.
4. Sensitivityissettoohigh.
1. Repositionthebulbawayfromthesensorornearby
objects.
2. Re-aimsensor.Reducerange.
3. SwitchtoAuto.
4. Reducerange.
Lightasheson
ando.
1. Heatorlightfromthebulbmaybeturningthelight
controlonando.
2. LightcontrolisintheTESTmodeandwarmingup.
3. Heatbeingreectedfromotherobjectsmaybeaecting
thesensor.
4. Ifeaveinstallation,lightshieldnotinstalledproperly.
1. Repositionthebulbawayfromthesensor.
2. Flashingisnormalundertheseconditions.
3. Re-aimsensor.Reducerange.
4. Installlightshieldaccordingtoinstructions.